The compiler wants to pad structures to a multiple of the native
datatype for the architecture, so a multiple of 4 on 32-bit platforms
and a multiple of 8 on 64-bit. Currently the size struct flow is
a multiple of 4, so the total size with padding varies depending on
the architecture, causing build asserts to fail. This explicitly pads
it out to a multiple of 8 for consistency.
uint8_t dl_dst[6]; /* Ethernet destination address. */
uint8_t nw_proto; /* IP protocol or low 8 bits of ARP opcode. */
uint8_t nw_tos; /* IP ToS (DSCP field, 6 bits). */
+ uint32_t reserved; /* Reserved for 64-bit packing. */
};
/* Assert that there are FLOW_SIG_SIZE bytes of significant data in "struct
* flow", followed by FLOW_PAD_SIZE bytes of padding. */
#define FLOW_SIG_SIZE (40 + FLOW_N_REGS * 4)
-#define FLOW_PAD_SIZE 0
+#define FLOW_PAD_SIZE 4
BUILD_ASSERT_DECL(offsetof(struct flow, nw_tos) == FLOW_SIG_SIZE - 1);
BUILD_ASSERT_DECL(sizeof(((struct flow *)0)->nw_tos) == 1);
BUILD_ASSERT_DECL(sizeof(struct flow) == FLOW_SIG_SIZE + FLOW_PAD_SIZE);