X-Git-Url: https://pintos-os.org/cgi-bin/gitweb.cgi?a=blobdiff_plain;f=utilities%2Fovs-vsctl.8.in;h=0d858a15025663aecb102167841699edeedf0669;hb=67e96a5dca90225358936b1392bba8b3207805b1;hp=64255b578350d5ed38fe02150a13f3506af9dfd5;hpb=21f7563cef5f3e5ab52c15ade58594c2dfdb7195;p=openvswitch diff --git a/utilities/ovs-vsctl.8.in b/utilities/ovs-vsctl.8.in index 64255b57..0d858a15 100644 --- a/utilities/ovs-vsctl.8.in +++ b/utilities/ovs-vsctl.8.in @@ -486,6 +486,9 @@ A bridge port. Records may be identified by port name. .IP "\fBInterface\fR" A network device attached to a port. Records may be identified by name. +.IP "\fBFlow_Table\fR" +Configuration for a particular OpenFlow flow table. Records may be +identified by name. .IP "\fBQoS\fR" Quality-of-service configuration for a \fBPort\fR. Records may be identified by port name. @@ -558,8 +561,10 @@ follow the syntax for the column's key type and value type, respectively. When multiple pairs are present (separated by spaces or a comma), duplicate keys are not allowed, and again the order is not important. Duplicate values are allowed. An empty map is represented -as \fB{}\fR, and curly braces may be optionally enclose non-empty maps -as well. +as \fB{}\fR. Curly braces may optionally enclose non-empty maps as +well (but use quotes to prevent the shell from expanding +\fBother-config={0=x,1=y}\fR into \fBother-config=0=x +other-config=1=y\fR, which may not have the desired effect). . .ST "Database Command Syntax" .IP "[\fB\-\-columns=\fIcolumn\fR[\fB,\fIcolumn\fR]...] \fBlist \fItable \fR[\fIrecord\fR]..." @@ -573,11 +578,56 @@ alphabetical order by column name. .IP "[\fB\-\-columns=\fIcolumn\fR[\fB,\fIcolumn\fR]...] \fBfind \fItable \fR[\fIcolumn\fR[\fB:\fIkey\fR]\fB=\fIvalue\fR]..." Lists the data in each record in \fItable\fR whose \fIcolumn\fR equals \fIvalue\fR or, if \fIkey\fR is specified, whose \fIcolumn\fR contains -a \fIkey\fR with the specified \fIvalue\fR. Any of the operators -\fB!=\fR, \fB<\fR, \fB>\fR, \fB<=\fR, or \fB>=\fR may be substituted -for \fB=\fR to test for inequality, less than, greater than, less than -or equal to, or greater than or equal to, respectively. (Don't forget -to escape \fB<\fR or \fB>\fR from interpretation by the shell.) +a \fIkey\fR with the specified \fIvalue\fR. The following operators +may be used where \fB=\fR is written in the syntax summary: +.RS +.IP "\fB= != < > <= >=\fR" +Selects records in which \fIcolumn\fR[\fB:\fIkey\fR] equals, does not +equal, is less than, is greater than, is less than or equal to, or is +greater than or equal to \fIvalue\fR, respectively. +.IP +Consider \fIcolumn\fR[\fB:\fIkey\fR] and \fIvalue\fR as sets of +elements. Identical sets are considered equal. Otherwise, if the +sets have different numbers of elements, then the set with more +elements is considered to be larger. Otherwise, consider a element +from each set pairwise, in increasing order within each set. The +first pair that differs determines the result. (For a column that +contains key-value pairs, first all the keys are compared, and values +are considered only if the two sets contain identical keys.) +.IP "\fB{=} {!=}\fR" +Test for set equality or inequality, respectively. +.IP "\fB{<=}\fR" +Selects records in which \fIcolumn\fR[\fB:\fIkey\fR] is a subset of +\fIvalue\fR. For example, \fBflood-vlans{<=}1,2\fR selects records in +which the \fBflood-vlans\fR column is the empty set or contains 1 or 2 +or both. +.IP "\fB{<}\fR" +Selects records in which \fIcolumn\fR[\fB:\fIkey\fR] is a proper +subset of \fIvalue\fR. For example, \fBflood-vlans{<}1,2\fR selects +records in which the \fBflood-vlans\fR column is the empty set or +contains 1 or 2 but not both. +.IP "\fB{>=} {>}\fR" +Same as \fB{<=}\fR and \fB{<}\fR, respectively, except that the +relationship is reversed. For example, \fBflood-vlans{>=}1,2\fR +selects records in which the \fBflood-vlans\fR column contains both 1 +and 2. +.RE +.IP +For arithmetic operators (\fB= != < > <= >=\fR), when \fIkey\fR is +specified but a particular record's \fIcolumn\fR does not contain +\fIkey\fR, the record is always omitted from the results. Thus, the +condition \fBother-config:mtu!=1500\fR matches records that have a +\fBmtu\fR key whose value is not 1500, but not those that lack an +\fBmtu\fR key. +.IP +For the set operators, when \fIkey\fR is specified but a particular +record's \fIcolumn\fR does not contain \fIkey\fR, the comparison is +done against an empty set. Thus, the condition +\fBother-config:mtu{!=}1500\fR matches records that have a \fBmtu\fR +key whose value is not 1500 and those that lack an \fBmtu\fR key. +.IP +Don't forget to escape \fB<\fR or \fB>\fR from interpretation by the +shell. .IP If \fB\-\-columns\fR is specified, only the requested columns are listed, in the specified order. Otherwise all columns are listed, in @@ -738,6 +788,12 @@ access port for VLAN 10, and configure it with an IP address: .IP .B "ifconfig vlan10 192.168.0.123" . +.PP +Add a GRE tunnel port \fBgre0\fR to remote IP address 1.2.3.4 to +bridge \fBbr0\fR: +.IP +.B "ovs\-vsctl add\-port br0 gre0 \-\- set Interface gre0 type=gre options:remote_ip=1.2.3.4" +. .SS "Port Mirroring" .PP Mirror all packets received or sent on \fBeth0\fR or \fBeth1\fR onto