X-Git-Url: https://pintos-os.org/cgi-bin/gitweb.cgi?a=blobdiff_plain;f=utilities%2Fovs-openflowd.8.in;h=9dec805e0d46bd797e08d792383629c25ff8dc37;hb=e20d7fc6504493b9b0654e1b8272a9d21dfdfbb9;hp=4c10d8d65aab8c78c437095c9cb88a6f8afdce93;hpb=812560d7cea7f618f8fd7110063e8dd039547006;p=openvswitch diff --git a/utilities/ovs-openflowd.8.in b/utilities/ovs-openflowd.8.in index 4c10d8d6..9dec805e 100644 --- a/utilities/ovs-openflowd.8.in +++ b/utilities/ovs-openflowd.8.in @@ -16,10 +16,15 @@ The \fBovs\-openflowd\fR program implements an OpenFlow switch using a flow-based datapath. \fBovs\-openflowd\fR connects to one or more OpenFlow controllers over TCP or SSL. .PP -The mandatory \fIdatapath\fR argument argument specifies the local datapath -to relay. It takes one of the following forms: -. -.so lib/dpif.man +For a more powerful alternative to \fBovs\-openflowd\fR, see +\fBovs\-vswitchd\fR(8). Do not run both daemons at the same time. +.PP +The mandatory \fIdatapath\fR argument argument specifies the local +datapath to relay. It takes the form [\fItype\fB@\fR]\fIname\fR, +where \fIname\fR is the network device associated with the datapath's +local port. If \fItype\fR is given, it specifies the datapath +provider of \fIname\fR, otherwise the default provider \fBsystem\fR is +assumed. . .PP The optional \fIcontroller\fR arguments specify how to connect to the @@ -27,6 +32,11 @@ OpenFlow controller or controllers. Each takes one of the following forms: . .so lib/vconn-active.man +.IP "\fBnone\fR" +Run without actively maintaining a connection to a remote OpenFlow +controller. (See the \fB\-\-listen\fR option, under \fBNetworking +Options\fR below, for another way to make OpenFlow connections to the +switch.) . .PP When multiple controllers are configured, \fBovs\-openflowd\fR @@ -170,7 +180,8 @@ the local port network device, and start the DHCP client afterward. .SS "OpenFlow Options" .TP \fB\-\-datapath\-id=\fIdpid\fR -Sets \fIdpid\fR, which must consist of exactly 16 hexadecimal digits, +Sets \fIdpid\fR, which must consist of exactly 16 hexadecimal digits +and may not be all-zero, as the datapath ID that the switch will use to identify itself to OpenFlow controllers. .IP @@ -425,9 +436,21 @@ switching. .SS "Logging Options" .so lib/vlog.man .SS "Other Options" +.so lib/unixctl.man .so lib/common.man .so lib/leak-checker.man . +.SH "RUNTIME MANAGEMENT COMMANDS" +\fBovs\-appctl\fR(8) can send commands to a running +\fBovs\-openflowd\fR process. The currently supported commands are +described below. +.SS "OVS\-OPENFLOWD COMMANDS" +These commands are specific to \fBovs\-openflowd\fR. +.IP "\fBexit\fR" +Causes \fBovs\-openflowd\fR to gracefully terminate. +.so ofproto/ofproto-unixctl.man +.so lib/vlog-unixctl.man +. .SH "SEE ALSO" . .BR ovs\-appctl (8),