X-Git-Url: https://pintos-os.org/cgi-bin/gitweb.cgi?a=blobdiff_plain;f=utilities%2Fovs-ofctl.8.in;h=439d3f5bc3184193ed8eb84ca7e2d34a5ef97fb1;hb=975ac5313396fbafe829b862335d90967b4d74f3;hp=eb98043ca46c084062cfe10d76618af1702df628;hpb=e3fdfed11b8c56aa6a8deffe11a552fed7e7adbc;p=openvswitch diff --git a/utilities/ovs-ofctl.8.in b/utilities/ovs-ofctl.8.in index eb98043c..439d3f5b 100644 --- a/utilities/ovs-ofctl.8.in +++ b/utilities/ovs-ofctl.8.in @@ -26,16 +26,15 @@ connecting to an OpenFlow switch. The following connection methods are supported: .RS -.TP -\fBssl:\fIhost\fR[\fB:\fIport\fR] -The specified SSL \fIport\fR (default: 6633) on the given remote -\fIhost\fR. The \fB--private-key\fR, \fB--certificate\fR, and -\fB--ca-cert\fR options are mandatory when this form is used. +.IP "\fBssl:\fIip\fR[\fB:\fIport\fR]" +The specified SSL \fIport\fR (default: 6633) on the host at the given +\fIip\fR, which must be expressed as an IP address (not a DNS name). +The \fB--private-key\fR, \fB--certificate\fR, and \fB--ca-cert\fR +options are mandatory when this form is used. -.TP -\fBtcp:\fIhost\fR[\fB:\fIport\fR] -The specified TCP \fIport\fR (default: 6633) on the given remote -\fIhost\fR. +.IP "\fBtcp:\fIip\fR[\fB:\fIport\fR]" +The specified TCP \fIport\fR (default: 6633) on the host at the given +\fIip\fR, which must be expressed as an IP address (not a DNS name). .TP \fBunix:\fIfile\fR @@ -147,13 +146,13 @@ syntax of \fIflows\fR. \fBmonitor \fIswitch\fR [\fImiss-len\fR [\fIsend-exp]] Connects to \fIswitch\fR and prints to the console all OpenFlow messages received. Usually, \fIswitch\fR should specify a connection -named on \fBsecchan\fR(8)'s \fB-l\fR or \fB--listen\fR command line +named on \fBovs\-openflowd\fR(8)'s \fB-l\fR or \fB--listen\fR command line option. If \fImiss-len\fR is provided, \fBovs\-ofctl\fR sends an OpenFlow ``set configuration'' message at connection setup time that requests \fImiss-len\fR bytes of each packet that misses the flow table. The -OpenFlow reference implementation not send these messages to the +OpenFlow reference implementation does not send these messages to the \fBovs\-ofctl monitor\fR client connection unless a nonzero value is specified on this argument. @@ -327,7 +326,7 @@ omitted, then the entire packet is sent. .IP \fBlocal\fR Outputs the packet on the ``local port,'' which corresponds to the \fBof\fIn\fR network device (see \fBCONTACTING THE CONTROLLER\fR in -\fBsecchan\fR(8) for information on the \fBof\fIn\fR network device). +\fBovs\-openflowd\fR(8) for information on the \fBof\fIn\fR network device). .IP \fBdrop\fR Discards the packet, so no further processing or forwarding takes place. @@ -353,6 +352,18 @@ Sets the source Ethernet address to \fImac\fR. .IP \fBmod_dl_dst\fB:\fImac\fR Sets the destination Ethernet address to \fImac\fR. + +.IP \fBmod_nw_src\fB:\fIip\fR +Sets the IPv4 source address to \fIip\fR. + +.IP \fBmod_nw_dst\fB:\fIip\fR +Sets the IPv4 destination address to \fIip\fR. + +.IP \fBmod_tp_src\fB:\fIport\fR +Sets the TCP or UDP source port to \fIport\fR. + +.IP \fBmod_tp_dst\fB:\fIport\fR +Sets the TCP or UDP destination port to \fIport\fR. .RE .IP @@ -471,7 +482,7 @@ The following examples assume that an OpenFlow switch on the local host has been configured to listen for management connections on a Unix domain socket named \fB@RUNDIR@/openflow.sock\fR, e.g. by specifying \fB--listen=punix:@RUNDIR@/openflow.sock\fR on the -\fBsecchan\fR(8) command line. +\fBovs\-openflowd\fR(8) command line. .TP \fBovs\-ofctl dump-tables unix:@RUNDIR@/openflow.sock\fR