Set of bridges managed by the daemon.
</column>
- <column name="managers">
- Remote database clients to which the Open vSwitch's database server
- should connect or to which it should listen.
- </column>
-
<column name="ssl">
SSL used globally by the daemon.
</column>
</dl>
</column>
</group>
+
+ <group title="Database Configuration">
+ <p>
+ These columns primarily configure the Open vSwitch database
+ (<code>ovsdb-server</code>), not the Open vSwitch switch
+ (<code>ovs-vswitchd</code>). The OVSDB database also uses the <ref
+ column="ssl"/> settings.
+ </p>
+
+ <p>
+ The Open vSwitch switch does read the database configuration to
+ determine remote IP addresses to which in-band control should apply.
+ </p>
+
+ <column name="manager_options">
+ Database clients to which the Open vSwitch database server should
+ connect or to which it should listen, along with options for how these
+ connection should be configured. See the <ref table="Manager"/> table
+ for more information.
+ </column>
+
+ <column name="managers">
+ <p>
+ Remote database clients to which the Open vSwitch's database server
+ should connect or to which it should listen. Adding an OVSDB target
+ to this set is equivalent to adding it to <ref
+ column="manager_options"/> with all of the default options.
+ </p>
+
+ <p>
+ Use of this column is deprecated and may be removed sometime in the
+ future. New applications should use and set <ref
+ column="manager_options"/> instead.
+ </p>
+ </column>
+ </group>
</table>
<table name="Bridge">
<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>
to set the hardware address of the local port and influence the
datapath ID.</dd>
+ <dt><code>in-band-queue</code></dt>
+ <dd>
+ A queue ID as a nonnegative integer. This sets the OpenFlow queue
+ ID that will be used by flows set up by in-band control on this
+ bridge. If unset, or if the port used by an in-band control flow
+ does not have QoS configured, or if the port does not have a queue
+ with the specified ID, the default queue is used instead.
+ </dd>
</dl>
</column>
</group>
for information on how this classifier works and how to configure it.
</dd>
</dl>
+ <dl>
+ <dt><code>linux-hfsc</code></dt>
+ <dd>
+ Linux "Hierarchical Fair Service Curve" classifier.
+ See <code>http://linux-ip.net/articles/hfsc.en/</code> for
+ information on how this classifier works.
+ </dd>
+ </dl>
</column>
<column name="queues">
<column name="other_config">
<p>Key-value pairs for configuring QoS features that depend on
<ref column="type"/>.</p>
- <p>The <code>linux-htb</code> class supports the following key-value
- pairs:</p>
+ <p>The <code>linux-htb</code> and <code>linux-hfsc</code> classes support
+ the following key-value pairs:</p>
<dl>
<dt><code>max-rate</code></dt>
<dd>Maximum rate shared by all queued traffic, in bit/s.
a queue with a larger value receives any. Specific priority
values are unimportant; only relative ordering matters.</dd>
</dl>
+ <p>The key-value pairs defined for <ref table="QoS"/> <ref table="QoS"
+ column="type"/> of <code>linux-hfsc</code> are:</p>
+ <dl>
+ <dt><code>min-rate</code></dt>
+ <dd>Minimum guaranteed bandwidth, in bit/s. Required.</dd>
+ <dt><code>max-rate</code></dt>
+ <dd>Maximum allowed bandwidth, in bit/s. Optional. If specified, the
+ queue's rate will not be allowed to exceed the specified value, even
+ if excess bandwidth is available. If unspecified, defaults to no
+ limit.</dd>
+ </dl>
</column>
<column name="external_ids">
</group>
</table>
+ <table name="Manager" title="OVSDB management connection.">
+ <p>
+ Configuration for a database connection to an Open vSwitch database
+ (OVSDB) client.
+ </p>
+
+ <p>
+ This table primarily configures the Open vSwitch database
+ (<code>ovsdb-server</code>), not the Open vSwitch switch
+ (<code>ovs-vswitchd</code>). The switch does read the table to determine
+ what connections should be treated as in-band.
+ </p>
+
+ <p>
+ The Open vSwitch database server can initiate and maintain active
+ connections to remote clients. It can also listen for database
+ connections.
+ </p>
+
+ <group title="Core Features">
+ <column name="target">
+ <p>Connection method for managers.</p>
+ <p>
+ The following connection methods are currently supported:
+ </p>
+ <dl>
+ <dt><code>ssl:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
+ <dd>
+ <p>
+ The specified SSL <var>port</var> (default: 6632) on the host at
+ the given <var>ip</var>, which must be expressed as an IP address
+ (not a DNS name). The <ref table="Open_vSwitch" column="ssl"/>
+ column in the <ref table="Open_vSwitch"/> table must point to a
+ valid SSL configuration when this form is used.
+ </p>
+ <p>
+ SSL support is an optional feature that is not always built as
+ part of Open vSwitch.
+ </p>
+ </dd>
+
+ <dt><code>tcp:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
+ <dd>
+ The specified TCP <var>port</var> (default: 6632) on the host at
+ the given <var>ip</var>, which must be expressed as an IP address
+ (not a DNS name).
+ </dd>
+ <dt><code>pssl:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
+ <dd>
+ <p>
+ Listens for SSL connections on the specified TCP <var>port</var>
+ (default: 6632). If <var>ip</var>, which must be expressed as an
+ IP address (not a DNS name), is specified, then connections are
+ restricted to the specified local IP address.
+ </p>
+ <p>
+ The <ref table="Open_vSwitch" column="ssl"/> column in the <ref
+ table="Open_vSwitch"/> table must point to a valid SSL
+ configuration when this form is used.
+ </p>
+ <p>
+ SSL support is an optional feature that is not always built as
+ part of Open vSwitch.
+ </p>
+ </dd>
+ <dt><code>ptcp:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
+ <dd>
+ Listens for connections on the specified TCP <var>port</var>
+ (default: 6632). If <var>ip</var>, which must be expressed as an
+ IP address (not a DNS name), is specified, then connections are
+ restricted to the specified local IP address.
+ </dd>
+ </dl>
+ <p>When multiple managers are configured, the <ref column="target"/>
+ values must be unique. Duplicate <ref column="target"/> values yield
+ unspecified results.</p>
+ </column>
+
+ <column name="connection_mode">
+ <p>
+ If it is specified, this setting must be one of the following strings
+ that describes how Open vSwitch contacts this OVSDB client over the
+ network:
+ </p>
+
+ <dl>
+ <dt><code>in-band</code></dt>
+ <dd>
+ In this mode, this connection's traffic travels over a bridge
+ managed by Open vSwitch. With this setting, Open vSwitch allows
+ traffic to and from the client regardless of the contents of the
+ OpenFlow flow table. (Otherwise, Open vSwitch would never be able
+ to connect to the client, because it did not have a flow to enable
+ it.) This is the most common connection mode because it is not
+ necessary to maintain two independent networks.
+ </dd>
+ <dt><code>out-of-band</code></dt>
+ <dd>
+ In this mode, the client's traffic uses a control network separate
+ from that managed by Open vSwitch, that is, Open vSwitch does not
+ use any of its own network devices to communicate with the client.
+ The control network must be configured separately, before or after
+ <code>ovs-vswitchd</code> is started.
+ </dd>
+ </dl>
+
+ <p>
+ If not specified, the default is implementation-specific.
+ </p>
+ </column>
+ </group>
+
+ <group title="Client Failure Detection and Handling">
+ <column name="max_backoff">
+ Maximum number of milliseconds to wait between connection attempts.
+ Default is implementation-specific.
+ </column>
+
+ <column name="inactivity_probe">
+ Maximum number of milliseconds of idle time on connection to the client
+ before sending an inactivity probe message. If Open vSwitch does not
+ communicate with the client for the specified number of seconds, it
+ will send a probe. If a response is not received for the same
+ additional amount of time, Open vSwitch assumes the connection has been
+ broken and attempts to reconnect. Default is implementation-specific.
+ </column>
+ </group>
+
+ <group title="Other Features">
+ <column name="external_ids">
+ Key-value pairs for use by external frameworks that integrate with Open
+ vSwitch, rather than by Open vSwitch itself. System integrators should
+ either use the Open vSwitch development mailing list to coordinate on
+ common key-value definitions, or choose key names that are likely to be
+ unique. No common key-value pairs are currently defined.
+ </column>
+ </group>
+ </table>
+
<table name="NetFlow">
A NetFlow target. NetFlow is a protocol that exports a number of
details about terminating IP flows, such as the principals involved