datapath: Harmonize [get|set]_skb_csum_pointers().
[openvswitch] / vswitchd / vswitch.xml
index bbe4af151e304a592453f32fdc3827f0ce8bc991..7b7a1ac928666a8399fa1e1d8bb84c872af204af 100644 (file)
         Set of bridges managed by the daemon.
       </column>
 
-      <column name="managers">
-        Remote database clients to which the Open vSwitch's database server
-        should connect or to which it should listen.
-      </column>
-
       <column name="ssl">
         SSL used globally by the daemon.
       </column>
         </dl>
       </column>
     </group>
+
+    <group title="Database Configuration">
+      <p>
+        These columns primarily configure the Open vSwitch database
+        (<code>ovsdb-server</code>), not the Open vSwitch switch
+        (<code>ovs-vswitchd</code>).  The OVSDB database also uses the <ref
+        column="ssl"/> settings.
+      </p>
+
+      <p>
+        The Open vSwitch switch does read the database configuration to
+        determine remote IP addresses to which in-band control should apply.
+      </p>
+
+      <column name="manager_options">
+        Database clients to which the Open vSwitch database server should
+        connect or to which it should listen, along with options for how these
+        connection should be configured.  See the <ref table="Manager"/> table
+        for more information.
+      </column>
+
+      <column name="managers">
+        <p>
+          Remote database clients to which the Open vSwitch's database server
+          should connect or to which it should listen.  Adding an OVSDB target
+          to this set is equivalent to adding it to <ref
+          column="manager_options"/> with all of the default options.
+        </p>
+
+        <p>
+          Use of this column is deprecated and may be removed sometime in the
+          future.  New applications should use and set <ref
+          column="manager_options"/> instead.
+        </p>
+      </column>
+    </group>
   </table>
 
   <table name="Bridge">
           </dl>
         </p>
         <p>If this value is unset, the default is implementation-specific.</p>
-        <p>When more than one controller is configured, 
+        <p>When more than one controller is configured,
           <ref column="fail_mode"/> is considered only when none of the
           configured controllers can be contacted.</p>
       </column>
         defined key-value pairs are:
         <dl>
           <dt><code>bridge-id</code></dt>
-          <dd>A unique identifier of the bridge.  On Citrix XenServer this 
+          <dd>A unique identifier of the bridge.  On Citrix XenServer this
             will commonly be the same as <code>xs-network-uuids</code>.</dd>
           <dt><code>xs-network-uuids</code></dt>
           <dd>Semicolon-delimited set of universally unique identifier(s) for
           <dt><code>datapath-id</code></dt>
           <dd>Exactly 16 hex
             digits to set the OpenFlow datapath ID to a specific
-            value.</dd>
+            value.  May not be all-zero.</dd>
+          <dt><code>disable-in-band</code></dt>
+          <dd>If set to <code>true</code>, disable in-band control on
+            the bridge regardless of controller and manager settings.</dd>
           <dt><code>hwaddr</code></dt>
           <dd>An Ethernet address in the form
             <var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>
             to set the hardware address of the local port and influence the
             datapath ID.</dd>
+          <dt><code>in-band-queue</code></dt>
+          <dd>
+            A queue ID as a nonnegative integer.  This sets the OpenFlow queue
+            ID that will be used by flows set up by in-band control on this
+            bridge.  If unset, or if the port used by an in-band control flow
+            does not have QoS configured, or if the port does not have a queue
+            with the specified ID, the default queue is used instead.
+          </dd>
         </dl>
       </column>
     </group>
       <p>A port that has more than one interface is a ``bonded port.''
         Bonding allows for load balancing and fail-over.  Open vSwitch
         supports ``source load balancing'' (SLB) bonding, which
-        assigns flows to slaves based on source MAC address, with
-        periodic rebalancing as traffic patterns change.  This form of
-        bonding does not require 802.3ad or other special support from
-        the upstream switch to which the slave devices are
-        connected.</p>
+        assigns flows to slaves based on source MAC address and output VLAN,
+        with periodic rebalancing as traffic patterns change.  This form of
+        bonding does not require 802.3ad or other special support from the
+        upstream switch to which the slave devices are connected.</p>
 
       <p>These columns apply only to bonded ports.  Their values are
         otherwise ignored.</p>
       <column name="qos">
         Quality of Service configuration for this port.
       </column>
-      
+
       <column name="mac">
         The MAC address to use for this port for the purpose of choosing the
         bridge's MAC address.  This column does not necessarily reflect the
         <p>Open vSwitch populates this column when the port number becomes
           known.  If the interface is successfully added,
           <ref column="ofport"/> will be set to a number between 1 and 65535
-          (generally either in the range 1 to 65280, exclusive, or 65534, the
+          (generally either in the range 1 to 65279, inclusive, or 65534, the
           port number for the OpenFlow ``local port'').  If the interface
           cannot be added then Open vSwitch sets this column
           to -1.</p>
              the same except one has an optional identifier and the other does
              not, the more specific one is matched first.  <code>in_key</code>
              is considered more specific than <code>local_ip</code> if a port
-             defines one and another port defines the other.  The following 
+             defines one and another port defines the other.  The following
              options may be specified in the <ref column="options"/> column:
             <dl>
               <dt><code>remote_ip</code></dt>
     </group>
 
     <group title="Other Features">
+
+      <column name="monitor">
+        Connectivity monitor configuration for this interface.
+      </column>
+
       <column name="external_ids">
         Key-value pairs for use by external frameworks that integrate
         with Open vSwitch, rather than by Open vSwitch itself.  System
             For Citrix XenServer, this is the value of the <code>MAC</code>
             field in the VIF record for this interface.</dd>
           <dt><code>iface-id</code></dt>
-          <dd>A system-unique identifier for the interface.  On XenServer, 
+          <dd>A system-unique identifier for the interface.  On XenServer,
             this will commonly be the same as <code>xs-vif-uuid</code>.</dd>
         </dl>
         <p>
             set.</dd>
           <dt><code>ipsec_psk</code></dt>
           <dd>Required key for GRE-over-IPsec interfaces.  Specifies a
-            pre-shared key for authentication that must be identical on 
+            pre-shared key for authentication that must be identical on
             both sides of the tunnel.  Additionally, the
             <code>ipsec_local_ip</code> key must also be set.</dd>
         </dl>
           for information on how this classifier works and how to configure it.
         </dd>
       </dl>
+      <dl>
+        <dt><code>linux-hfsc</code></dt>
+        <dd>
+          Linux "Hierarchical Fair Service Curve" classifier.
+          See <code>http://linux-ip.net/articles/hfsc.en/</code> for
+          information on how this classifier works.
+        </dd>
+      </dl>
     </column>
 
     <column name="queues">
     <column name="other_config">
       <p>Key-value pairs for configuring QoS features that depend on
         <ref column="type"/>.</p>
-      <p>The <code>linux-htb</code> class supports the following key-value
-        pairs:</p>
+      <p>The <code>linux-htb</code> and <code>linux-hfsc</code> classes support
+          the following key-value pairs:</p>
       <dl>
         <dt><code>max-rate</code></dt>
         <dd>Maximum rate shared by all queued traffic, in bit/s.
           a queue with a larger value receives any.  Specific priority
           values are unimportant; only relative ordering matters.</dd>
       </dl>
+      <p>The key-value pairs defined for <ref table="QoS"/> <ref table="QoS"
+        column="type"/> of <code>linux-hfsc</code> are:</p>
+      <dl>
+        <dt><code>min-rate</code></dt>
+        <dd>Minimum guaranteed bandwidth, in bit/s.  Required.</dd>
+        <dt><code>max-rate</code></dt>
+        <dd>Maximum allowed bandwidth, in bit/s.  Optional.  If specified, the
+          queue's rate will not be allowed to exceed the specified value, even
+          if excess bandwidth is available.  If unspecified, defaults to no
+          limit.</dd>
+      </dl>
     </column>
 
     <column name="external_ids">
     </column>
   </table>
 
+  <table name="Monitor" title="Connectivity Monitor configuration">
+    <p>
+      A <ref table="Monitor"/> attaches to an <ref table="Interface"/> to
+      implement 802.1ag Connectivity Fault Management (CFM).  CFM allows a
+      group of Maintenance Points (MPs) called a Maintenance Association (MA)
+      to detect connectivity problems with each other.  MPs within a MA should
+      have complete and exclusive interconnectivity.  This is verified by
+      occasionally broadcasting Continuity Check Messages (CCMs) at a
+      configurable transmission interval.  A <ref table="Monitor"/> is
+      responsible for collecting data about other MPs in its MA and
+      broadcasting CCMs.
+    </p>
+
+    <group title="Monitor Configuration">
+      <column name="mpid">
+        A Maintenance Point ID (MPID) uniquely identifies each endpoint within
+        a Maintenance Association (see <ref column="ma_name"/>).  The MPID is
+        used to identify this <ref table="Monitor"/> to other endpoints in the
+        MA.
+      </column>
+
+      <column name="remote_mps">
+        A set of <ref table="Maintenance_Points"/> which this
+        <ref table="Monitor"/> should have connectivity to.  If this
+        <ref table="Monitor"/> does not have connectivity to any MPs in this
+        set, or has connectivity to any MPs not in this set, a fault is
+        signaled.
+      </column>
+
+      <column name="ma_name">
+        A Maintenance Association (MA) name pairs with a Maintenance Domain
+        (MD) name to uniquely identify a MA.  A MA is a group of endpoints who
+        have complete and exclusive interconnectivity. Defaults to
+        <code>ovs</code> if unset.
+      </column>
+
+      <column name="md_name">
+        A Maintenance Domain name pairs with a Maintenance Association name to
+        uniquely identify a MA. Defaults to <code>ovs</code> if unset.
+      </column>
+
+      <column name="interval">
+        The transmission interval of CCMs in milliseconds.  Three missed CCMs
+        indicate a connectivity fault.  Defaults to 1000ms.
+      </column>
+    </group>
+
+    <group title="Monitor Status">
+      <column name="unexpected_remote_mpids">
+        A set of MPIDs representing MPs to which this <ref table="Monitor"/>
+        has detected connectivity that are not in the
+        <ref column="remote_mps"/> set.  This <ref table="Monitor"/> should not
+        have connectivity to any MPs not listed in <ref column="remote_mps"/>.
+        Thus, if this set is non-empty a fault is indicated.
+      </column>
+
+      <column name="unexpected_remote_maids">
+        A set of MAIDs representing foreign Maintenance Associations (MAs)
+        which this <ref table="Monitor"/> has detected connectivity to. A
+        <ref table="Monitor"/> should not have connectivity to a Maintenance
+        Association other than its own.  Thus, if this set is non-empty a fault
+        is indicated.
+      </column>
+
+      <column name="fault">
+        Indicates a Connectivity Fault caused by a configuration error, a down
+        remote MP, or unexpected connectivity to a remote MAID or remote MP.
+      </column>
+    </group>
+  </table>
+
+  <table name="Maintenance_Point" title="Maintenance Point configuration">
+    <p>
+      A <ref table="Maintenance_Point"/> represents a MP which a
+      <ref table="Monitor"/> has or should have connectivity to.
+    </p>
+
+    <group title="Maintenance_Point Configuration">
+      <column name="mpid">
+        A Maintenance Point ID (MPID) uniquely identifies each endpoint within
+        a Maintenance Association. All MPs within a MA should have a unique
+        MPID.
+      </column>
+    </group>
+
+    <group title="Maintenance_Point Status">
+      <column name="fault">
+        Indicates a connectivity fault.
+      </column>
+    </group>
+  </table>
+
   <table name="Mirror" title="Port mirroring (SPAN/RSPAN).">
     <p>A port mirror within a <ref table="Bridge"/>.</p>
     <p>A port mirror configures a bridge to send selected frames to special
     <p>
       Open vSwitch supports two kinds of OpenFlow controllers:
     </p>
-    
+
     <dl>
       <dt>Primary controllers</dt>
       <dd>
     </group>
   </table>
 
+  <table name="Manager" title="OVSDB management connection.">
+    <p>
+      Configuration for a database connection to an Open vSwitch database
+      (OVSDB) client.
+    </p>
+
+    <p>
+      This table primarily configures the Open vSwitch database
+      (<code>ovsdb-server</code>), not the Open vSwitch switch
+      (<code>ovs-vswitchd</code>).  The switch does read the table to determine
+      what connections should be treated as in-band.
+    </p>
+
+    <p>
+      The Open vSwitch database server can initiate and maintain active
+      connections to remote clients.  It can also listen for database
+      connections.
+    </p>
+
+    <group title="Core Features">
+      <column name="target">
+        <p>Connection method for managers.</p>
+        <p>
+          The following connection methods are currently supported:
+        </p>
+        <dl>
+          <dt><code>ssl:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
+          <dd>
+            <p>
+              The specified SSL <var>port</var> (default: 6632) on the host at
+              the given <var>ip</var>, which must be expressed as an IP address
+              (not a DNS name).  The <ref table="Open_vSwitch" column="ssl"/>
+              column in the <ref table="Open_vSwitch"/> table must point to a
+              valid SSL configuration when this form is used.
+            </p>
+            <p>
+              SSL support is an optional feature that is not always built as
+              part of Open vSwitch.
+            </p>
+          </dd>
+
+          <dt><code>tcp:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
+          <dd>
+            The specified TCP <var>port</var> (default: 6632) on the host at
+            the given <var>ip</var>, which must be expressed as an IP address
+            (not a DNS name).
+          </dd>
+          <dt><code>pssl:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
+          <dd>
+            <p>
+              Listens for SSL connections on the specified TCP <var>port</var>
+              (default: 6632).  If <var>ip</var>, which must be expressed as an
+              IP address (not a DNS name), is specified, then connections are
+              restricted to the specified local IP address.
+            </p>
+            <p>
+              The <ref table="Open_vSwitch" column="ssl"/> column in the <ref
+              table="Open_vSwitch"/> table must point to a valid SSL
+              configuration when this form is used.
+            </p>
+            <p>
+              SSL support is an optional feature that is not always built as
+              part of Open vSwitch.
+            </p>
+          </dd>
+          <dt><code>ptcp:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
+          <dd>
+            Listens for connections on the specified TCP <var>port</var>
+            (default: 6632).  If <var>ip</var>, which must be expressed as an
+            IP address (not a DNS name), is specified, then connections are
+            restricted to the specified local IP address.
+          </dd>
+        </dl>
+        <p>When multiple managers are configured, the <ref column="target"/>
+        values must be unique.  Duplicate <ref column="target"/> values yield
+        unspecified results.</p>
+      </column>
+
+      <column name="connection_mode">
+        <p>
+          If it is specified, this setting must be one of the following strings
+          that describes how Open vSwitch contacts this OVSDB client over the
+          network:
+        </p>
+
+        <dl>
+          <dt><code>in-band</code></dt>
+          <dd>
+            In this mode, this connection's traffic travels over a bridge
+            managed by Open vSwitch.  With this setting, Open vSwitch allows
+            traffic to and from the client regardless of the contents of the
+            OpenFlow flow table.  (Otherwise, Open vSwitch would never be able
+            to connect to the client, because it did not have a flow to enable
+            it.)  This is the most common connection mode because it is not
+            necessary to maintain two independent networks.
+          </dd>
+          <dt><code>out-of-band</code></dt>
+          <dd>
+            In this mode, the client's traffic uses a control network separate
+            from that managed by Open vSwitch, that is, Open vSwitch does not
+            use any of its own network devices to communicate with the client.
+            The control network must be configured separately, before or after
+            <code>ovs-vswitchd</code> is started.
+          </dd>
+        </dl>
+
+        <p>
+          If not specified, the default is implementation-specific.
+        </p>
+      </column>
+    </group>
+
+    <group title="Client Failure Detection and Handling">
+      <column name="max_backoff">
+        Maximum number of milliseconds to wait between connection attempts.
+        Default is implementation-specific.
+      </column>
+
+      <column name="inactivity_probe">
+        Maximum number of milliseconds of idle time on connection to the client
+        before sending an inactivity probe message.  If Open vSwitch does not
+        communicate with the client for the specified number of seconds, it
+        will send a probe.  If a response is not received for the same
+        additional amount of time, Open vSwitch assumes the connection has been
+        broken and attempts to reconnect.  Default is implementation-specific.
+      </column>
+    </group>
+
+    <group title="Other Features">
+      <column name="external_ids">
+        Key-value pairs for use by external frameworks that integrate with Open
+        vSwitch, rather than by Open vSwitch itself.  System integrators should
+        either use the Open vSwitch development mailing list to coordinate on
+        common key-value definitions, or choose key names that are likely to be
+        unique.  No common key-value pairs are currently defined.
+      </column>
+    </group>
+  </table>
+
   <table name="NetFlow">
     A NetFlow target.  NetFlow is a protocol that exports a number of
     details about terminating IP flows, such as the principals involved