VLOG_ERR("bridge %s: problem setting netflow collectors",
br->name);
}
+ svec_destroy(&nf_hosts);
/* Update the controller and related settings. It would be more
* straightforward to call this from bridge_reconfigure_one(), but we
}
iface->tag = tag_create_random();
}
+ port_update_bond_compat(port);
}
static void
goto done;
} else {
/* Drop all multicast packets for which we have learned a different
- * input port, because we probably sent the packet on one slaves
+ * input port, because we probably sent the packet on one slave
* and got it back on the active slave. Broadcast ARP replies are
* an exception to this rule: the host has moved to another
* switch. */
ofpbuf_init(&packet, 128);
error = n_packets = n_errors = 0;
LIST_FOR_EACH (e, struct mac_entry, lru_node, &br->ml->lrus) {
- static const char s[] = "Open vSwitch Bond Failover";
union ofp_action actions[2], *a;
- struct eth_header *eth;
- struct llc_snap_header *llc_snap;
uint16_t dp_ifidx;
tag_type tags = 0;
flow_t flow;
continue;
}
- /* Compose packet to send. */
- ofpbuf_clear(&packet);
- eth = ofpbuf_put_zeros(&packet, ETH_HEADER_LEN);
- llc_snap = ofpbuf_put_zeros(&packet, LLC_SNAP_HEADER_LEN);
- ofpbuf_put(&packet, s, sizeof s); /* Includes null byte. */
- ofpbuf_put(&packet, e->mac, ETH_ADDR_LEN);
-
- memcpy(eth->eth_dst, eth_addr_broadcast, ETH_ADDR_LEN);
- memcpy(eth->eth_src, e->mac, ETH_ADDR_LEN);
- eth->eth_type = htons(packet.size - ETH_HEADER_LEN);
-
- llc_snap->llc.llc_dsap = LLC_DSAP_SNAP;
- llc_snap->llc.llc_ssap = LLC_SSAP_SNAP;
- llc_snap->llc.llc_cntl = LLC_CNTL_SNAP;
- memcpy(llc_snap->snap.snap_org, "\x00\x23\x20", 3);
- llc_snap->snap.snap_type = htons(0xf177); /* Random number. */
-
/* Compose actions. */
memset(actions, 0, sizeof actions);
a = actions;
/* Send packet. */
n_packets++;
+ compose_benign_packet(&packet, "Open vSwitch Bond Failover", 0xf177,
+ e->mac);
flow_extract(&packet, ODPP_NONE, &flow);
retval = ofproto_send_packet(br->ofproto, &flow, actions, a - actions,
&packet);
struct iface *iface = port->ifaces[i];
struct compat_bond_slave *slave = &bond.slaves[i];
slave->name = iface->name;
- slave->up = ((iface->enabled && iface->delay_expires == LLONG_MAX) ||
- (!iface->enabled && iface->delay_expires != LLONG_MAX));
+
+ /* We need to make the same determination as the Linux bonding
+ * code to determine whether a slave should be consider "up".
+ * The Linux function bond_miimon_inspect() supports four
+ * BOND_LINK_* states:
+ *
+ * - BOND_LINK_UP: carrier detected, updelay has passed.
+ * - BOND_LINK_FAIL: carrier lost, downdelay in progress.
+ * - BOND_LINK_DOWN: carrier lost, downdelay has passed.
+ * - BOND_LINK_BACK: carrier detected, updelay in progress.
+ *
+ * The function bond_info_show_slave() only considers BOND_LINK_UP
+ * to be "up" and anything else to be "down".
+ */
+ slave->up = iface->enabled && iface->delay_expires == LLONG_MAX;
if (slave->up) {
bond.up = true;
}
int *vlans;
size_t i;
bool mirror_all_ports;
+ bool any_ports_specified;
/* Get output port. */
out_port_name = cfg_get_key(0, "mirror.%s.%s.output.port",
cfg_get_all_keys(&src_ports, "%s.select.src-port", pfx);
cfg_get_all_keys(&dst_ports, "%s.select.dst-port", pfx);
cfg_get_all_keys(&ports, "%s.select.port", pfx);
+ any_ports_specified = src_ports.n || dst_ports.n || ports.n;
svec_append(&src_ports, &ports);
svec_append(&dst_ports, &ports);
svec_destroy(&ports);
prune_ports(m, &src_ports);
prune_ports(m, &dst_ports);
+ if (any_ports_specified && !src_ports.n && !dst_ports.n) {
+ VLOG_ERR("%s: none of the specified ports exist; "
+ "disabling port mirror %s", pfx, pfx);
+ mirror_destroy(m);
+ goto exit;
+ }
/* Get all the vlans, and drop duplicate and invalid vlans. */
svec_init(&vlan_strings);
}
/* Clean up. */
+exit:
svec_destroy(&src_ports);
svec_destroy(&dst_ports);
free(pfx);