xenserver: Fix issue with deleting network UUID on VLAN destruction
[openvswitch] / vswitchd / ovs-vswitchd.conf.5.in
index 7f989b40fd8b49b9d6409aa8ed2907c497037ff8..7c3c87f3e5c1346556e065e7ac169204b8aa13c5 100644 (file)
@@ -412,18 +412,24 @@ port.eth1.ingress.policing-burst=20
 
 .fi
 .SS "NetFlow v5 Flow Logging"
 
 .fi
 .SS "NetFlow v5 Flow Logging"
-NetFlow is a protocol that exports a number of details about terminating 
-IP flows, such as the principals involved and duration.  A bridge may be 
-configured to send NetFlow v5 records to NetFlow collectors when flows 
-end.  To enable, define the key \fBnetflow.\fIbridge\fB.host\fR for each 
-collector in the form \fIip\fB:\fIport\fR.  Records from \fIbridge\fR 
+NetFlow is a protocol that exports a number of details about terminating
+IP flows, such as the principals involved and duration.  A bridge may be
+configured to send NetFlow v5 records to NetFlow collectors when flows
+end.  To enable, define the key \fBnetflow.\fIbridge\fB.host\fR for each
+collector in the form \fIip\fB:\fIport\fR.  Records from \fIbridge\fR
 will be sent to each \fIip\fR on UDP \fIport\fR.  The \fIip\fR must
 be specified numerically, not as a DNS name.
 
 will be sent to each \fIip\fR on UDP \fIport\fR.  The \fIip\fR must
 be specified numerically, not as a DNS name.
 
-The NetFlow messages will use the datapath index for the engine type and id.  
-This can be overridden with the \fBnetflow.\fIbridge\fB.engine-type\fR and 
+In addition to terminating flows, NetFlow can also send records at a set
+interval for flows that are still active.  This interval can be configured
+by defining the key \fBnetflow.\fIbridge\fB\.active-timeout\fR.  The value
+is in seconds.  An active timeout of 0 will disable this functionality.  By
+default there is timeout value of 600 seconds.
+
+The NetFlow messages will use the datapath index for the engine type and id.
+This can be overridden with the \fBnetflow.\fIbridge\fB.engine-type\fR and
 \fBnetflow.\fIbridge\fB.engine-id\fR, respectively.  Each takes a value
 \fBnetflow.\fIbridge\fB.engine-id\fR, respectively.  Each takes a value
-between 0 and 255, inclusive. 
+between 0 and 255, inclusive.
 
 Many NetFlow collectors do not expect multiple virtual switches to be
 sending messages from the same host, and they do not store the engine
 
 Many NetFlow collectors do not expect multiple virtual switches to be
 sending messages from the same host, and they do not store the engine
@@ -431,8 +437,15 @@ information which could be used to disambiguate the traffic.  To prevent
 flows from multiple switches appearing as if they came on the interface,
 add \fBnetflow.\fIbridge\fB.add-id-to-iface=true\fR to the configuration
 file.  This will place the least significant 7 bits of the engine id
 flows from multiple switches appearing as if they came on the interface,
 add \fBnetflow.\fIbridge\fB.add-id-to-iface=true\fR to the configuration
 file.  This will place the least significant 7 bits of the engine id
-into the most significant bits of the ingress and egress interface fields 
-of flow records.  By default, this behavior is disabled.
+into the most significant bits of the ingress and egress interface fields
+of flow records.  When this option is enabled, a maximum of 508 ports are
+supported.  By default, this behavior is disabled.
+
+The egress interface field normally contains the OpenFlow port number,
+however, certain port values have special meaning: 0xFFFF indicates
+flooding, 0xFFFE is multiple controller-specified output interfaces, and
+0xFFFD means that packets from the flow were dropped.  If add-id-to-iface
+is enabled then these values become 0x1FF, 0x1FE, and 0x1FD respectively.
 
 The following syntax sends NetFlow records for \fBmybr\fR to the NetFlow
 collector \fBnflow.example.com\fR on UDP port \fB9995\fR:
 
 The following syntax sends NetFlow records for \fBmybr\fR to the NetFlow
 collector \fBnflow.example.com\fR on UDP port \fB9995\fR: