Factor out common code from utilities that multiplex commands.
[openvswitch] / utilities / ovs-dpctl.8.in
index c43d4ffa013af746e081d2aed37a3c26d246b631..dc4d4568182180fe4adbb2413e306d7e0e96bf39 100644 (file)
@@ -1,4 +1,4 @@
-.TH ovs\-dpctl 8 "March 2009" "Open vSwitch" "Open vSwitch Manual"
+.TH ovs\-dpctl 8 "August 2009" "Open vSwitch" "Open vSwitch Manual"
 .ds PN ovs\-dpctl
 
 .SH NAME
 .ds PN ovs\-dpctl
 
 .SH NAME
@@ -70,11 +70,6 @@ A \fInetdev\fR may be followed by a comma-separated list of options.
 The following options are currently supported:
 
 .RS
 The following options are currently supported:
 
 .RS
-.IP "\fBport=\fIportno\fR"
-Specifies \fIportno\fR (a number between 1 and 255) as the port number
-at which \fInetdev\fR will be attached.  By default, \fBadd\-if\fR
-automatically selects the lowest available port number.
-
 .IP "\fBinternal\fR"
 Instead of attaching an existing \fInetdev\fR, creates an internal
 port (analogous to the local port) with that name.
 .IP "\fBinternal\fR"
 Instead of attaching an existing \fInetdev\fR, creates an internal
 port (analogous to the local port) with that name.
@@ -85,6 +80,10 @@ port (analogous to the local port) with that name.
 Removes each \fInetdev\fR from the list of network devices datapath
 \fIdp\fR monitors.
 
 Removes each \fInetdev\fR from the list of network devices datapath
 \fIdp\fR monitors.
 
+.TP
+\fBdump-dps\fR
+Prints the name of each configured datapath on a separate line.
+
 .TP
 \fBshow \fR[\fIdp\fR...]
 Prints a summary of configured datapaths, including their datapath
 .TP
 \fBshow \fR[\fIdp\fR...]
 Prints a summary of configured datapaths, including their datapath
@@ -115,9 +114,10 @@ up may be confused about their disappearance.
 .IP "\fBdump-groups \fIdp\fR"
 Prints to the console the sets of port groups maintained by datapath
 \fIdp\fR.  Ordinarily there are at least 2 port groups in a datapath
 .IP "\fBdump-groups \fIdp\fR"
 Prints to the console the sets of port groups maintained by datapath
 \fIdp\fR.  Ordinarily there are at least 2 port groups in a datapath
-that \fBsecchan\fR or \fBvswitch\fR is controlling: group 0 contains
+that \fBovs\-openflowd\fR or \fBovs\-vswitch\fR is controlling: group
+0 contains
 all ports except those disabled by STP, and group 1 contains all
 all ports except those disabled by STP, and group 1 contains all
-ports.  Additional groups might be used in the future.
+ports.  Additional or different groups might be used in the future.
 
 This command is primarily useful for debugging Open vSwitch.  OpenFlow
 does not have a concept of port groups.
 
 This command is primarily useful for debugging Open vSwitch.  OpenFlow
 does not have a concept of port groups.
@@ -146,7 +146,7 @@ Creates datapath number 0.
 Adds two network devices to the new datapath.
 
 .PP
 Adds two network devices to the new datapath.
 
 .PP
-At this point one would ordinarily start \fBsecchan\fR(8) on
+At this point one would ordinarily start \fBovs\-openflowd\fR(8) on
 \fBdp0\fR, transforming \fBdp0\fR into an OpenFlow switch.  Then, when
 the switch and the datapath is no longer needed:
 
 \fBdp0\fR, transforming \fBdp0\fR into an OpenFlow switch.  Then, when
 the switch and the datapath is no longer needed:
 
@@ -160,6 +160,6 @@ Deletes the datapath.
 
 .SH "SEE ALSO"
 
 
 .SH "SEE ALSO"
 
-.BR secchan (8),
 .BR ovs\-appctl (8),
 .BR ovs\-appctl (8),
+.BR ovs\-openflowd (8),
 .BR ovs\-vswitchd (8)
 .BR ovs\-vswitchd (8)