7be78911899240ebad175e3dfa1e8f46bc3fb706
[openvswitch] / vswitchd / vswitch.xml
1 <?xml version="1.0" encoding="utf-8"?>
2 <database title="Open vSwitch Configuration Database">
3   <p>
4     A database with this schema holds the configuration for one Open
5     vSwitch daemon.  The top-level configuration for the daemon is the
6     <ref table="Open_vSwitch"/> table, which must have exactly one
7     record.  Records in other tables are significant only when they
8     can be reached directly or indirectly from the <ref
9     table="Open_vSwitch"/> table.  Records that are not reachable from
10     the <ref table="Open_vSwitch"/> table are automatically deleted
11     from the database, except for records in a few distinguished
12     ``root set'' tables.
13   </p>
14
15   <h2>Common Columns</h2>
16
17   <p>
18     Most tables contain two special columns, named <code>other_config</code>
19     and <code>external_ids</code>.  These columns have the same form and
20     purpose each place that they appear, so we describe them here to save space
21     later.
22   </p>
23
24   <dl>
25     <dt><code>other_config</code>: map of string-string pairs</dt>
26     <dd>
27       <p>
28         Key-value pairs for configuring rarely used features.  Supported keys,
29         along with the forms taken by their values, are documented individually
30         for each table.
31       </p>
32       <p>
33         A few tables do not have <code>other_config</code> columns because no
34         key-value pairs have yet been defined for them.
35       </p>
36     </dd>
37
38     <dt><code>external_ids</code>: map of string-string pairs</dt>
39     <dd>
40       Key-value pairs for use by external frameworks that integrate with Open
41       vSwitch, rather than by Open vSwitch itself.  System integrators should
42       either use the Open vSwitch development mailing list to coordinate on
43       common key-value definitions, or choose key names that are likely to be
44       unique.  In some cases, where key-value pairs have been defined that are
45       likely to be widely useful, they are documented individually for each
46       table.
47     </dd>
48   </dl>
49
50   <table name="Open_vSwitch" title="Open vSwitch configuration.">
51     Configuration for an Open vSwitch daemon.  There must be exactly
52     one record in the <ref table="Open_vSwitch"/> table.
53
54     <group title="Configuration">
55       <column name="bridges">
56         Set of bridges managed by the daemon.
57       </column>
58
59       <column name="ssl">
60         SSL used globally by the daemon.
61       </column>
62
63       <column name="external_ids" key="system-id">
64         A unique identifier for the Open vSwitch's physical host.
65         The form of the identifier depends on the type of the host.
66         On a Citrix XenServer, this will likely be the same as
67         <ref column="external_ids" key="xs-system-uuid"/>.
68       </column>
69
70       <column name="external_ids" key="xs-system-uuid">
71         The Citrix XenServer universally unique identifier for the physical
72         host as displayed by <code>xe host-list</code>.
73       </column>
74     </group>
75
76     <group title="Status">
77       <column name="next_cfg">
78         Sequence number for client to increment.  When a client modifies
79         any part of the database configuration and wishes to wait for
80         Open vSwitch to finish applying the changes, it may increment
81         this sequence number.
82       </column>
83
84       <column name="cur_cfg">
85         Sequence number that Open vSwitch sets to the current value of
86         <ref column="next_cfg"/> after it finishes applying a set of
87         configuration changes.
88       </column>
89
90       <column name="capabilities">
91         Describes functionality supported by the hardware and software platform
92         on which this Open vSwitch is based.  Clients should not modify this
93         column.  See the <ref table="Capability"/> description for defined
94         capability categories and the meaning of associated
95         <ref table="Capability"/> records.
96       </column>
97
98       <group title="Statistics">
99         <p>
100           The <code>statistics</code> column contains key-value pairs that
101           report statistics about a system running an Open vSwitch.  These are
102           updated periodically (currently, every 5 seconds).  Key-value pairs
103           that cannot be determined or that do not apply to a platform are
104           omitted.
105         </p>
106
107         <column name="other_config" key="enable-statistics"
108                 type='{"type": "boolean"}'>
109           Statistics are disabled by default to avoid overhead in the common
110           case when statistics gathering is not useful.  Set this value to
111           <code>true</code> to enable populating the <ref column="statistics"/>
112           column or to <code>false</code> to explicitly disable it.
113         </column>
114
115         <column name="statistics" key="cpu"
116                 type='{"type": "integer", "minInteger": 1}'>
117           <p>
118             Number of CPU processors, threads, or cores currently online and
119             available to the operating system on which Open vSwitch is running,
120             as an integer.  This may be less than the number installed, if some
121             are not online or if they are not available to the operating
122             system.
123           </p>
124           <p>
125             Open vSwitch userspace processes are not multithreaded, but the
126             Linux kernel-based datapath is.
127           </p>
128         </column>
129
130         <column name="statistics" key="load_average">
131           A comma-separated list of three floating-point numbers,
132           representing the system load average over the last 1, 5, and 15
133           minutes, respectively.
134         </column>
135
136         <column name="statistics" key="memory">
137           <p>
138             A comma-separated list of integers, each of which represents a
139             quantity of memory in kilobytes that describes the operating
140             system on which Open vSwitch is running.  In respective order,
141             these values are:
142           </p>
143
144           <ol>
145             <li>Total amount of RAM allocated to the OS.</li>
146             <li>RAM allocated to the OS that is in use.</li>
147             <li>RAM that can be flushed out to disk or otherwise discarded
148             if that space is needed for another purpose.  This number is
149             necessarily less than or equal to the previous value.</li>
150             <li>Total disk space allocated for swap.</li>
151             <li>Swap space currently in use.</li>
152           </ol>
153
154           <p>
155             On Linux, all five values can be determined and are included.  On
156             other operating systems, only the first two values can be
157             determined, so the list will only have two values.
158           </p>
159         </column>
160
161         <column name="statistics" key="process_NAME">
162           <p>
163             One such key-value pair, with <code>NAME</code> replaced by
164             a process name, will exist for each running Open vSwitch
165             daemon process, with <var>name</var> replaced by the
166             daemon's name (e.g. <code>process_ovs-vswitchd</code>).  The
167             value is a comma-separated list of integers.  The integers
168             represent the following, with memory measured in kilobytes
169             and durations in milliseconds:
170           </p>
171
172           <ol>
173             <li>The process's virtual memory size.</li>
174             <li>The process's resident set size.</li>
175             <li>The amount of user and system CPU time consumed by the
176             process.</li>
177             <li>The number of times that the process has crashed and been
178             automatically restarted by the monitor.</li>
179             <li>The duration since the process was started.</li>
180             <li>The duration for which the process has been running.</li>
181           </ol>
182
183           <p>
184             The interpretation of some of these values depends on whether the
185             process was started with the <option>--monitor</option>.  If it
186             was not, then the crash count will always be 0 and the two
187             durations will always be the same.  If <option>--monitor</option>
188             was given, then the crash count may be positive; if it is, the
189             latter duration is the amount of time since the most recent crash
190             and restart.
191           </p>
192
193           <p>
194             There will be one key-value pair for each file in Open vSwitch's
195             ``run directory'' (usually <code>/var/run/openvswitch</code>)
196             whose name ends in <code>.pid</code>, whose contents are a
197             process ID, and which is locked by a running process.  The
198             <var>name</var> is taken from the pidfile's name.
199           </p>
200
201           <p>
202             Currently Open vSwitch is only able to obtain all of the above
203             detail on Linux systems.  On other systems, the same key-value
204             pairs will be present but the values will always be the empty
205             string.
206           </p>
207         </column>
208
209         <column name="statistics" key="file_systems">
210           <p>
211             A space-separated list of information on local, writable file
212             systems.  Each item in the list describes one file system and
213             consists in turn of a comma-separated list of the following:
214           </p>
215
216           <ol>
217             <li>Mount point, e.g. <code>/</code> or <code>/var/log</code>.
218             Any spaces or commas in the mount point are replaced by
219             underscores.</li>
220             <li>Total size, in kilobytes, as an integer.</li>
221             <li>Amount of storage in use, in kilobytes, as an integer.</li>
222           </ol>
223
224           <p>
225             This key-value pair is omitted if there are no local, writable
226             file systems or if Open vSwitch cannot obtain the needed
227             information.
228           </p>
229         </column>
230       </group>
231     </group>
232
233     <group title="Version Reporting">
234       <p>
235         These columns report the types and versions of the hardware and
236         software running Open vSwitch.  We recommend in general that software
237         should test whether specific features are supported instead of relying
238         on version number checks.  These values are primarily intended for
239         reporting to human administrators.
240       </p>
241
242       <column name="ovs_version">
243         The Open vSwitch version number, e.g. <code>1.1.0</code>.
244         If Open vSwitch was configured with a build number, then it is
245         also included, e.g. <code>1.1.0+build6579</code>.
246       </column>
247
248       <column name="db_version">
249         <p>
250           The database schema version number in the form
251           <code><var>major</var>.<var>minor</var>.<var>tweak</var></code>,
252           e.g. <code>1.2.3</code>.  Whenever the database schema is changed in
253           a non-backward compatible way (e.g. deleting a column or a table),
254           <var>major</var> is incremented.  When the database schema is changed
255           in a backward compatible way (e.g. adding a new column),
256           <var>minor</var> is incremented.  When the database schema is changed
257           cosmetically (e.g. reindenting its syntax), <var>tweak</var> is
258           incremented.
259         </p>
260
261         <p>
262           The schema version is part of the database schema, so it can also be
263           retrieved by fetching the schema using the Open vSwitch database
264           protocol.
265         </p>
266       </column>
267
268       <column name="system_type">
269         <p>
270           An identifier for the type of system on top of which Open vSwitch
271           runs, e.g. <code>XenServer</code> or <code>KVM</code>.
272         </p>
273         <p>
274           System integrators are responsible for choosing and setting an
275           appropriate value for this column.
276         </p>
277       </column>
278
279       <column name="system_version">
280         <p>
281           The version of the system identified by <ref column="system_type"/>,
282           e.g. <code>5.6.100-39265p</code> on XenServer 5.6.100 build 39265.
283         </p>
284         <p>
285           System integrators are responsible for choosing and setting an
286           appropriate value for this column.
287         </p>
288       </column>
289
290     </group>
291
292     <group title="Database Configuration">
293       <p>
294         These columns primarily configure the Open vSwitch database
295         (<code>ovsdb-server</code>), not the Open vSwitch switch
296         (<code>ovs-vswitchd</code>).  The OVSDB database also uses the <ref
297         column="ssl"/> settings.
298       </p>
299
300       <p>
301         The Open vSwitch switch does read the database configuration to
302         determine remote IP addresses to which in-band control should apply.
303       </p>
304
305       <column name="manager_options">
306         Database clients to which the Open vSwitch database server should
307         connect or to which it should listen, along with options for how these
308         connection should be configured.  See the <ref table="Manager"/> table
309         for more information.
310       </column>
311     </group>
312
313     <group title="Common Columns">
314       The overall purpose of these columns is described under <code>Common
315       Columns</code> at the beginning of this document.
316
317       <column name="other_config"/>
318       <column name="external_ids"/>
319     </group>
320   </table>
321
322   <table name="Bridge">
323     <p>
324       Configuration for a bridge within an
325       <ref table="Open_vSwitch"/>.
326     </p>
327     <p>
328       A <ref table="Bridge"/> record represents an Ethernet switch with one or
329       more ``ports,'' which are the <ref table="Port"/> records pointed to by
330       the <ref table="Bridge"/>'s <ref column="ports"/> column.
331     </p>
332
333     <group title="Core Features">
334       <column name="name">
335         Bridge identifier.  Should be alphanumeric and no more than about 8
336         bytes long.  Must be unique among the names of ports, interfaces, and
337         bridges on a host.
338       </column>
339
340       <column name="ports">
341         Ports included in the bridge.
342       </column>
343
344       <column name="mirrors">
345         Port mirroring configuration.
346       </column>
347
348       <column name="netflow">
349         NetFlow configuration.
350       </column>
351
352       <column name="sflow">
353         sFlow configuration.
354       </column>
355
356       <column name="flood_vlans">
357         <p>
358           VLAN IDs of VLANs on which MAC address learning should be disabled,
359           so that packets are flooded instead of being sent to specific ports
360           that are believed to contain packets' destination MACs.  This should
361           ordinarily be used to disable MAC learning on VLANs used for
362           mirroring (RSPAN VLANs).  It may also be useful for debugging.
363         </p>
364         <p>
365           SLB bonding (see the <ref table="Port" column="bond_mode"/> column in
366           the <ref table="Port"/> table) is incompatible with
367           <code>flood_vlans</code>.  Consider using another bonding mode or
368           a different type of mirror instead.
369         </p>
370       </column>
371     </group>
372
373     <group title="OpenFlow Configuration">
374       <column name="controller">
375         <p>
376           OpenFlow controller set.  If unset, then no OpenFlow controllers
377           will be used.
378         </p>
379
380         <p>
381           If there are primary controllers, removing all of them clears the
382           flow table.  If there are no primary controllers, adding one also
383           clears the flow table.  Other changes to the set of controllers, such
384           as adding or removing a service controller, adding another primary
385           controller to supplement an existing primary controller, or removing
386           only one of two primary controllers, have no effect on the flow
387           table.
388         </p>
389       </column>
390
391       <column name="flow_tables">
392         Configuration for OpenFlow tables.  Each pair maps from an OpenFlow
393         table ID to configuration for that table.
394       </column>
395
396       <column name="fail_mode">
397         <p>When a controller is configured, it is, ordinarily, responsible
398         for setting up all flows on the switch.  Thus, if the connection to
399         the controller fails, no new network connections can be set up.
400         If the connection to the controller stays down long enough,
401         no packets can pass through the switch at all.  This setting
402         determines the switch's response to such a situation.  It may be set
403         to one of the following:
404         <dl>
405           <dt><code>standalone</code></dt>
406           <dd>If no message is received from the controller for three
407           times the inactivity probe interval
408           (see <ref column="inactivity_probe"/>), then Open vSwitch
409           will take over responsibility for setting up flows.  In
410           this mode, Open vSwitch causes the bridge to act like an
411           ordinary MAC-learning switch.  Open vSwitch will continue
412           to retry connecting to the controller in the background
413           and, when the connection succeeds, it will discontinue its
414           standalone behavior.</dd>
415           <dt><code>secure</code></dt>
416           <dd>Open vSwitch will not set up flows on its own when the
417           controller connection fails or when no controllers are
418           defined.  The bridge will continue to retry connecting to
419           any defined controllers forever.</dd>
420         </dl>
421         </p>
422         <p>If this value is unset, the default is implementation-specific.</p>
423         <p>When more than one controller is configured,
424         <ref column="fail_mode"/> is considered only when none of the
425         configured controllers can be contacted.</p>
426         <p>
427           Changing <ref column="fail_mode"/> when no primary controllers are
428           configured clears the flow table.
429         </p>
430       </column>
431
432       <column name="datapath_id">
433         Reports the OpenFlow datapath ID in use.  Exactly 16 hex digits.
434         (Setting this column has no useful effect.  Set <ref
435         column="other-config" key="datapath-id"/> instead.)
436       </column>
437
438       <column name="other_config" key="datapath-id">
439         Exactly 16 hex digits to set the OpenFlow datapath ID to a specific
440         value.  May not be all-zero.
441       </column>
442
443       <column name="other_config" key="disable-in-band"
444               type='{"type": "boolean"}'>
445         If set to <code>true</code>, disable in-band control on the bridge
446         regardless of controller and manager settings.
447       </column>
448
449       <column name="other_config" key="in-band-queue"
450               type='{"type": "integer", "minInteger": 0, "maxInteger": 4294967295}'>
451         A queue ID as a nonnegative integer.  This sets the OpenFlow queue ID
452         that will be used by flows set up by in-band control on this bridge.
453         If unset, or if the port used by an in-band control flow does not have
454         QoS configured, or if the port does not have a queue with the specified
455         ID, the default queue is used instead.
456       </column>
457     </group>
458
459     <group title="Spanning Tree Configuration">
460       The IEEE 802.1D Spanning Tree Protocol (STP) is a network protocol
461       that ensures loop-free topologies.  It allows redundant links to
462       be included in the network to provide automatic backup paths if
463       the active links fails.
464
465       <column name="stp_enable">
466         Enable spanning tree on the bridge.  By default, STP is disabled
467         on bridges.  Bond, internal, and mirror ports are not supported
468         and will not participate in the spanning tree.
469       </column>
470
471       <column name="other_config" key="stp-system-id">
472         The bridge's STP identifier (the lower 48 bits of the bridge-id)
473         in the form
474         <var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>.
475         By default, the identifier is the MAC address of the bridge.
476       </column>
477
478       <column name="other_config" key="stp-priority"
479               type='{"type": "integer", "minInteger": 0, "maxInteger": 65535}'>
480         The bridge's relative priority value for determining the root
481         bridge (the upper 16 bits of the bridge-id).  A bridge with the
482         lowest bridge-id is elected the root.  By default, the priority
483         is 0x8000.
484       </column>
485
486       <column name="other_config" key="stp-hello-time"
487               type='{"type": "integer", "minInteger": 1, "maxInteger": 10}'>
488         The interval between transmissions of hello messages by
489         designated ports, in seconds.  By default the hello interval is
490         2 seconds.
491       </column>
492
493       <column name="other_config" key="stp-max-age"
494               type='{"type": "integer", "minInteger": 6, "maxInteger": 40}'>
495         The maximum age of the information transmitted by the bridge
496         when it is the root bridge, in seconds.  By default, the maximum
497         age is 20 seconds.
498       </column>
499
500       <column name="other_config" key="stp-forward-delay"
501               type='{"type": "integer", "minInteger": 4, "maxInteger": 30}'>
502         The delay to wait between transitioning root and designated
503         ports to <code>forwarding</code>, in seconds.  By default, the
504         forwarding delay is 15 seconds.
505       </column>
506     </group>
507
508     <group title="Other Features">
509       <column name="datapath_type">
510         Name of datapath provider.  The kernel datapath has
511         type <code>system</code>.  The userspace datapath has
512         type <code>netdev</code>.
513       </column>
514
515       <column name="external_ids" key="bridge-id">
516         A unique identifier of the bridge.  On Citrix XenServer this will
517         commonly be the same as
518         <ref column="external_ids" key="xs-network-uuids"/>.
519       </column>
520
521       <column name="external_ids" key="xs-network-uuids">
522         Semicolon-delimited set of universally unique identifier(s) for the
523         network with which this bridge is associated on a Citrix XenServer
524         host.  The network identifiers are RFC 4122 UUIDs as displayed by,
525         e.g., <code>xe network-list</code>.
526       </column>
527
528       <column name="other_config" key="hwaddr">
529         An Ethernet address in the form
530         <var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>
531         to set the hardware address of the local port and influence the
532         datapath ID.
533       </column>
534
535       <column name="other_config" key="flow-eviction-threshold"
536               type='{"type": "integer", "minInteger": 0}'>
537         <p>
538           A number of flows as a nonnegative integer.  This sets number of
539           flows at which eviction from the kernel flow table will be triggered.
540           If there are a large number of flows then increasing this value to
541           around the number of flows present can result in reduced CPU usage
542           and packet loss.
543         </p>
544         <p>
545           The default is 1000.  Values below 100 will be rounded up to 100.
546         </p>
547       </column>
548
549       <column name="other_config" key="forward-bpdu"
550               type='{"type": "boolean"}'>
551         Option to allow forwarding of BPDU frames when NORMAL action is
552         invoked.  Frames with reserved Ethernet addresses (e.g. STP
553         BPDU) will be forwarded when this option is enabled and the
554         switch is not providing that functionality.  If STP is enabled
555         on the port, STP BPDUs will never be forwarded.  If the Open
556         vSwitch bridge is used to connect different Ethernet networks,
557         and if Open vSwitch node does not run STP, then this option
558         should be enabled.  Default is disabled, set to
559         <code>true</code> to enable.
560       </column>
561
562       <column name="other_config" key="mac-aging-time"
563               type='{"type": "integer", "minInteger": 1}'>
564         <p>
565           The maximum number of seconds to retain a MAC learning entry for
566           which no packets have been seen.  The default is currently 300
567           seconds (5 minutes).  The value, if specified, is forced into a
568           reasonable range, currently 15 to 3600 seconds.
569         </p>
570
571         <p>
572           A short MAC aging time allows a network to more quickly detect that a
573           host is no longer connected to a switch port.  However, it also makes
574           it more likely that packets will be flooded unnecessarily, when they
575           are addressed to a connected host that rarely transmits packets.  To
576           reduce the incidence of unnecessary flooding, use a MAC aging time
577           longer than the maximum interval at which a host will ordinarily
578           transmit packets.
579         </p>
580       </column>
581     </group>
582
583     <group title="Bridge Status">
584       <p>
585         Status information about bridges.
586       </p>
587       <column name="status">
588         Key-value pairs that report bridge status.
589       </column>
590       <column name="status" key="stp_bridge_id">
591         <p>
592           The bridge-id (in hex) used in spanning tree advertisements.
593           Configuring the bridge-id is described in the
594           <code>stp-system-id</code> and <code>stp-priority</code> keys
595           of the <code>other_config</code> section earlier.
596         </p>
597       </column>
598       <column name="status" key="stp_designated_root">
599         <p>
600           The designated root (in hex) for this spanning tree.
601         </p>
602       </column>
603       <column name="status" key="stp_root_path_cost">
604         <p>
605           The path cost of reaching the designated bridge.  A lower
606           number is better.
607         </p>
608       </column>
609     </group>
610
611     <group title="Common Columns">
612       The overall purpose of these columns is described under <code>Common
613       Columns</code> at the beginning of this document.
614
615       <column name="other_config"/>
616       <column name="external_ids"/>
617     </group>
618   </table>
619
620   <table name="Port" table="Port or bond configuration.">
621     <p>A port within a <ref table="Bridge"/>.</p>
622     <p>Most commonly, a port has exactly one ``interface,'' pointed to by its
623     <ref column="interfaces"/> column.  Such a port logically
624     corresponds to a port on a physical Ethernet switch.  A port
625     with more than one interface is a ``bonded port'' (see
626     <ref group="Bonding Configuration"/>).</p>
627     <p>Some properties that one might think as belonging to a port are actually
628     part of the port's <ref table="Interface"/> members.</p>
629
630     <column name="name">
631       Port name.  Should be alphanumeric and no more than about 8
632       bytes long.  May be the same as the interface name, for
633       non-bonded ports.  Must otherwise be unique among the names of
634       ports, interfaces, and bridges on a host.
635     </column>
636
637     <column name="interfaces">
638       The port's interfaces.  If there is more than one, this is a
639       bonded Port.
640     </column>
641
642     <group title="VLAN Configuration">
643       <p>Bridge ports support the following types of VLAN configuration:</p>
644       <dl>
645         <dt>trunk</dt>
646         <dd>
647           <p>
648             A trunk port carries packets on one or more specified VLANs
649             specified in the <ref column="trunks"/> column (often, on every
650             VLAN).  A packet that ingresses on a trunk port is in the VLAN
651             specified in its 802.1Q header, or VLAN 0 if the packet has no
652             802.1Q header.  A packet that egresses through a trunk port will
653             have an 802.1Q header if it has a nonzero VLAN ID.
654           </p>
655
656           <p>
657             Any packet that ingresses on a trunk port tagged with a VLAN that
658             the port does not trunk is dropped.
659           </p>
660         </dd>
661
662         <dt>access</dt>
663         <dd>
664           <p>
665             An access port carries packets on exactly one VLAN specified in the
666             <ref column="tag"/> column.  Packets egressing on an access port
667             have no 802.1Q header.
668           </p>
669
670           <p>
671             Any packet with an 802.1Q header with a nonzero VLAN ID that
672             ingresses on an access port is dropped, regardless of whether the
673             VLAN ID in the header is the access port's VLAN ID.
674           </p>
675         </dd>
676
677         <dt>native-tagged</dt>
678         <dd>
679           A native-tagged port resembles a trunk port, with the exception that
680           a packet without an 802.1Q header that ingresses on a native-tagged
681           port is in the ``native VLAN'' (specified in the <ref column="tag"/>
682           column).
683         </dd>
684
685         <dt>native-untagged</dt>
686         <dd>
687           A native-untagged port resembles a native-tagged port, with the
688           exception that a packet that egresses on a native-untagged port in
689           the native VLAN will not have an 802.1Q header.
690         </dd>
691       </dl>
692       <p>
693         A packet will only egress through bridge ports that carry the VLAN of
694         the packet, as described by the rules above.
695       </p>
696
697       <column name="vlan_mode">
698         <p>
699           The VLAN mode of the port, as described above.  When this column is
700           empty, a default mode is selected as follows:
701         </p>
702         <ul>
703           <li>
704             If <ref column="tag"/> contains a value, the port is an access
705             port.  The <ref column="trunks"/> column should be empty.
706           </li>
707           <li>
708             Otherwise, the port is a trunk port.  The <ref column="trunks"/>
709             column value is honored if it is present.
710           </li>
711         </ul>
712       </column>
713
714       <column name="tag">
715         <p>
716           For an access port, the port's implicitly tagged VLAN.  For a
717           native-tagged or native-untagged port, the port's native VLAN.  Must
718           be empty if this is a trunk port.
719         </p>
720       </column>
721
722       <column name="trunks">
723         <p>
724           For a trunk, native-tagged, or native-untagged port, the 802.1Q VLAN
725           or VLANs that this port trunks; if it is empty, then the port trunks
726           all VLANs.  Must be empty if this is an access port.
727         </p>
728         <p>
729           A native-tagged or native-untagged port always trunks its native
730           VLAN, regardless of whether <ref column="trunks"/> includes that
731           VLAN.
732         </p>
733       </column>
734
735       <column name="other_config" key="priority-tags"
736               type='{"type": "boolean"}'>
737         <p>
738           An 802.1Q header contains two important pieces of information: a VLAN
739           ID and a priority.  A frame with a zero VLAN ID, called a
740           ``priority-tagged'' frame, is supposed to be treated the same way as
741           a frame without an 802.1Q header at all (except for the priority).
742         </p>
743
744         <p>
745           However, some network elements ignore any frame that has 802.1Q
746           header at all, even when the VLAN ID is zero.  Therefore, by default
747           Open vSwitch does not output priority-tagged frames, instead omitting
748           the 802.1Q header entirely if the VLAN ID is zero.  Set this key to
749           <code>true</code> to enable priority-tagged frames on a port.
750         </p>
751
752         <p>
753           Regardless of this setting, Open vSwitch omits the 802.1Q header on
754           output if both the VLAN ID and priority would be zero.
755         </p>
756
757         <p>
758           All frames output to native-tagged ports have a nonzero VLAN ID, so
759           this setting is not meaningful on native-tagged ports.
760         </p>
761       </column>
762     </group>
763
764     <group title="Bonding Configuration">
765       <p>A port that has more than one interface is a ``bonded port.'' Bonding
766       allows for load balancing and fail-over.  Some kinds of bonding will
767       work with any kind of upstream switch:</p>
768
769       <dl>
770         <dt><code>balance-slb</code></dt>
771         <dd>
772           Balances flows among slaves based on source MAC address and output
773           VLAN, with periodic rebalancing as traffic patterns change.
774         </dd>
775
776         <dt><code>active-backup</code></dt>
777         <dd>
778           Assigns all flows to one slave, failing over to a backup slave when
779           the active slave is disabled.
780         </dd>
781       </dl>
782
783       <p>
784         The following modes require the upstream switch to support 802.3ad with
785         successful LACP negotiation:
786       </p>
787
788       <dl>
789         <dt><code>balance-tcp</code></dt>
790         <dd>
791           Balances flows among slaves based on L2, L3, and L4 protocol
792           information such as destination MAC address, IP address, and TCP
793           port.
794         </dd>
795
796         <dt><code>stable</code></dt>
797         <dd>
798           <p>Attempts to always assign a given flow to the same slave
799           consistently.  In an effort to maintain stability, no load
800           balancing is done.  Uses a similar hashing strategy to
801           <code>balance-tcp</code>, always taking into account L3 and L4
802           fields even if LACP negotiations are unsuccessful. </p>
803           <p>Slave selection decisions are made based on <ref table="Interface"
804           column="other_config" key="bond-stable-id"/> if set.  Otherwise,
805           OpenFlow port number is used.  Decisions are consistent across all
806           <code>ovs-vswitchd</code> instances with equivalent
807           <ref table="Interface" column="other_config" key="bond-stable-id"/>
808           values.</p>
809         </dd>
810       </dl>
811
812       <p>These columns apply only to bonded ports.  Their values are
813       otherwise ignored.</p>
814
815       <column name="bond_mode">
816         <p>The type of bonding used for a bonded port.  Defaults to
817         <code>active-backup</code> if unset.
818         </p>
819       </column>
820
821       <column name="other_config" key="bond-hash-basis"
822               type='{"type": "integer"}'>
823         An integer hashed along with flows when choosing output slaves in load
824         balanced bonds.  When changed, all flows will be assigned different
825         hash values possibly causing slave selection decisions to change.  Does
826         not affect bonding modes which do not employ load balancing such as
827         <code>active-backup</code>.
828       </column>
829
830       <group title="Link Failure Detection">
831         <p>
832           An important part of link bonding is detecting that links are down so
833           that they may be disabled.  These settings determine how Open vSwitch
834           detects link failure.
835         </p>
836
837         <column name="other_config" key="bond-detect-mode"
838                 type='{"type": "string", "enum": ["set", ["carrier", "miimon"]]}'>
839           The means used to detect link failures.  Defaults to
840           <code>carrier</code> which uses each interface's carrier to detect
841           failures.  When set to <code>miimon</code>, will check for failures
842           by polling each interface's MII.
843         </column>
844
845         <column name="other_config" key="bond-miimon-interval"
846                 type='{"type": "integer"}'>
847           The interval, in milliseconds, between successive attempts to poll
848           each interface's MII.  Relevant only when <ref column="other_config"
849           key="bond-detect-mode"/> is <code>miimon</code>.
850         </column>
851
852         <column name="bond_updelay">
853           <p>
854             The number of milliseconds for which carrier must stay up on an
855             interface before the interface is considered to be up.  Specify
856             <code>0</code> to enable the interface immediately.
857           </p>
858
859           <p>
860             This setting is honored only when at least one bonded interface is
861             already enabled.  When no interfaces are enabled, then the first
862             bond interface to come up is enabled immediately.
863           </p>
864         </column>
865
866         <column name="bond_downdelay">
867           The number of milliseconds for which carrier must stay down on an
868           interface before the interface is considered to be down.  Specify
869           <code>0</code> to disable the interface immediately.
870         </column>
871       </group>
872
873       <group title="LACP Configuration">
874         <p>
875           LACP, the Link Aggregation Control Protocol, is an IEEE standard that
876           allows switches to automatically detect that they are connected by
877           multiple links and aggregate across those links.  These settings
878           control LACP behavior.
879         </p>
880
881         <column name="lacp">
882           Configures LACP on this port.  LACP allows directly connected
883           switches to negotiate which links may be bonded.  LACP may be enabled
884           on non-bonded ports for the benefit of any switches they may be
885           connected to.  <code>active</code> ports are allowed to initiate LACP
886           negotiations.  <code>passive</code> ports are allowed to participate
887           in LACP negotiations initiated by a remote switch, but not allowed to
888           initiate such negotiations themselves.  If LACP is enabled on a port
889           whose partner switch does not support LACP, the bond will be
890           disabled.  Defaults to <code>off</code> if unset.
891         </column>
892
893         <column name="other_config" key="lacp-system-id">
894           The LACP system ID of this <ref table="Port"/>.  The system ID of a
895           LACP bond is used to identify itself to its partners.  Must be a
896           nonzero MAC address. Defaults to the bridge Ethernet address if
897           unset.
898         </column>
899
900         <column name="other_config" key="lacp-system-priority"
901                 type='{"type": "integer", "minInteger": 1, "maxInteger": 65535}'>
902           The LACP system priority of this <ref table="Port"/>.  In LACP
903           negotiations, link status decisions are made by the system with the
904           numerically lower priority.
905         </column>
906
907         <column name="other_config" key="lacp-time">
908           <p>
909             The LACP timing which should be used on this <ref table="Port"/>.
910             Possible values are <code>fast</code>, <code>slow</code> and a
911             positive number of milliseconds.  By default <code>slow</code> is
912             used.  When configured to be <code>fast</code> LACP heartbeats are
913             requested at a rate of once per second causing connectivity
914             problems to be detected more quickly.  In <code>slow</code> mode,
915             heartbeats are requested at a rate of once every 30 seconds.
916           </p>
917
918           <p>
919             Users may manually set a heartbeat transmission rate to increase
920             the fault detection speed further.  When manually set, OVS expects
921             the partner switch to be configured with the same transmission
922             rate.  Manually setting <code>lacp-time</code> to something other
923             than <code>fast</code> or <code>slow</code> is not supported by the
924             LACP specification.
925           </p>
926         </column>
927
928         <column name="other_config" key="lacp-heartbeat"
929                 type='{"type": "boolean"}'>
930           Treat LACP like a simple heartbeat protocol for link state
931           monitoring.  Most features of the LACP protocol are disabled
932           when this mode is in use.  The default if not specified is
933           <code>false</code>.
934         </column>
935       </group>
936
937       <group title="SLB Configuration">
938         <p>
939           These settings control behavior when a bond is in
940           <code>balance-slb</code> mode, regardless of whether the bond was
941           intentionally configured in SLB mode or it fell back to SLB mode
942           because LACP negotiation failed.
943         </p>
944
945         <column name="other_config" key="bond-rebalance-interval"
946                 type='{"type": "integer", "minInteger": 0, "maxInteger": 10000}'>
947           For a load balanced bonded port, the number of milliseconds between
948           successive attempts to rebalance the bond, that is, to move flows
949           from one interface on the bond to another in an attempt to keep usage
950           of each interface roughly equal.  If zero, load balancing is disabled
951           on the bond (carrier status changes still cause flows to move).  If
952           less than 1000ms, the rebalance interval will be 1000ms.
953         </column>
954       </group>
955
956       <column name="bond_fake_iface">
957         For a bonded port, whether to create a fake internal interface with the
958         name of the port.  Use only for compatibility with legacy software that
959         requires this.
960       </column>
961     </group>
962
963     <group title="Spanning Tree Configuration">
964       <column name="other_config" key="stp-enable"
965               type='{"type": "boolean"}'>
966         If spanning tree is enabled on the bridge, member ports are
967         enabled by default (with the exception of bond, internal, and
968         mirror ports which do not work with STP).  If this column's
969         value is <code>false</code> spanning tree is disabled on the
970         port.
971       </column>
972
973        <column name="other_config" key="stp-port-num"
974                type='{"type": "integer", "minInteger": 1, "maxInteger": 255}'>
975         The port number used for the lower 8 bits of the port-id.  By
976         default, the numbers will be assigned automatically.  If any
977         port's number is manually configured on a bridge, then they
978         must all be.
979       </column>
980
981        <column name="other_config" key="stp-port-priority"
982                type='{"type": "integer", "minInteger": 0, "maxInteger": 255}'>
983         The port's relative priority value for determining the root
984         port (the upper 8 bits of the port-id).  A port with a lower
985         port-id will be chosen as the root port.  By default, the
986         priority is 0x80.
987       </column>
988
989        <column name="other_config" key="stp-path-cost"
990                type='{"type": "integer", "minInteger": 0, "maxInteger": 65535}'>
991         Spanning tree path cost for the port.  A lower number indicates
992         a faster link.  By default, the cost is based on the maximum
993         speed of the link.
994       </column>
995     </group>
996
997     <group title="Other Features">
998       <column name="qos">
999         Quality of Service configuration for this port.
1000       </column>
1001
1002       <column name="mac">
1003         The MAC address to use for this port for the purpose of choosing the
1004         bridge's MAC address.  This column does not necessarily reflect the
1005         port's actual MAC address, nor will setting it change the port's actual
1006         MAC address.
1007       </column>
1008
1009       <column name="fake_bridge">
1010         Does this port represent a sub-bridge for its tagged VLAN within the
1011         Bridge?  See ovs-vsctl(8) for more information.
1012       </column>
1013
1014       <column name="external_ids" key="fake-bridge-id-*">
1015         External IDs for a fake bridge (see the <ref column="fake_bridge"/>
1016         column) are defined by prefixing a <ref table="Bridge"/> <ref
1017         table="Bridge" column="external_ids"/> key with
1018         <code>fake-bridge-</code>,
1019         e.g. <code>fake-bridge-xs-network-uuids</code>.
1020       </column>
1021     </group>
1022
1023     <group title="Port Status">
1024       <p>
1025         Status information about ports attached to bridges.
1026       </p>
1027       <column name="status">
1028         Key-value pairs that report port status.
1029       </column>
1030       <column name="status" key="stp_port_id">
1031         <p>
1032           The port-id (in hex) used in spanning tree advertisements for
1033           this port.  Configuring the port-id is described in the
1034           <code>stp-port-num</code> and <code>stp-port-priority</code>
1035           keys of the <code>other_config</code> section earlier.
1036         </p>
1037       </column>
1038       <column name="status" key="stp_state"
1039               type='{"type": "string", "enum": ["set",
1040                             ["disabled", "listening", "learning",
1041                              "forwarding", "blocking"]]}'>
1042         <p>
1043           STP state of the port.
1044         </p>
1045       </column>
1046       <column name="status" key="stp_sec_in_state"
1047               type='{"type": "integer", "minInteger": 0}'>
1048         <p>
1049           The amount of time (in seconds) port has been in the current
1050           STP state.
1051         </p>
1052       </column>
1053       <column name="status" key="stp_role"
1054               type='{"type": "string", "enum": ["set",
1055                             ["root", "designated", "alternate"]]}'>
1056         <p>
1057           STP role of the port.
1058         </p>
1059       </column>
1060     </group>
1061
1062     <group title="Port Statistics">
1063       <p>
1064         Key-value pairs that report port statistics.
1065       </p>
1066       <group title="Statistics: STP transmit and receive counters">
1067         <column name="statistics" key="stp_tx_count">
1068           Number of STP BPDUs sent on this port by the spanning
1069           tree library.
1070         </column>
1071         <column name="statistics" key="stp_rx_count">
1072           Number of STP BPDUs received on this port and accepted by the
1073           spanning tree library.
1074         </column>
1075         <column name="statistics" key="stp_error_count">
1076           Number of bad STP BPDUs received on this port.  Bad BPDUs
1077           include runt packets and those with an unexpected protocol ID.
1078         </column>
1079       </group>
1080     </group>
1081
1082     <group title="Common Columns">
1083       The overall purpose of these columns is described under <code>Common
1084       Columns</code> at the beginning of this document.
1085
1086       <column name="other_config"/>
1087       <column name="external_ids"/>
1088     </group>
1089   </table>
1090
1091   <table name="Interface" title="One physical network device in a Port.">
1092     An interface within a <ref table="Port"/>.
1093
1094     <group title="Core Features">
1095       <column name="name">
1096         Interface name.  Should be alphanumeric and no more than about 8 bytes
1097         long.  May be the same as the port name, for non-bonded ports.  Must
1098         otherwise be unique among the names of ports, interfaces, and bridges
1099         on a host.
1100       </column>
1101
1102       <column name="mac">
1103         <p>Ethernet address to set for this interface.  If unset then the
1104         default MAC address is used:</p>
1105         <ul>
1106           <li>For the local interface, the default is the lowest-numbered MAC
1107           address among the other bridge ports, either the value of the
1108           <ref table="Port" column="mac"/> in its <ref table="Port"/> record,
1109           if set, or its actual MAC (for bonded ports, the MAC of its slave
1110           whose name is first in alphabetical order).  Internal ports and
1111           bridge ports that are used as port mirroring destinations (see the
1112           <ref table="Mirror"/> table) are ignored.</li>
1113           <li>For other internal interfaces, the default MAC is randomly
1114           generated.</li>
1115           <li>External interfaces typically have a MAC address associated with
1116           their hardware.</li>
1117         </ul>
1118         <p>Some interfaces may not have a software-controllable MAC
1119         address.</p>
1120       </column>
1121
1122       <column name="ofport">
1123         <p>OpenFlow port number for this interface.  Unlike most columns, this
1124         column's value should be set only by Open vSwitch itself.  Other
1125         clients should set this column to an empty set (the default) when
1126         creating an <ref table="Interface"/>.</p>
1127         <p>Open vSwitch populates this column when the port number becomes
1128         known.  If the interface is successfully added,
1129         <ref column="ofport"/> will be set to a number between 1 and 65535
1130         (generally either in the range 1 to 65279, inclusive, or 65534, the
1131         port number for the OpenFlow ``local port'').  If the interface
1132         cannot be added then Open vSwitch sets this column
1133         to -1.</p>
1134       </column>
1135     </group>
1136
1137     <group title="System-Specific Details">
1138       <column name="type">
1139         <p>
1140           The interface type, one of:
1141         </p>
1142
1143         <dl>
1144           <dt><code>system</code></dt>
1145           <dd>An ordinary network device, e.g. <code>eth0</code> on Linux.
1146           Sometimes referred to as ``external interfaces'' since they are
1147           generally connected to hardware external to that on which the Open
1148           vSwitch is running.  The empty string is a synonym for
1149           <code>system</code>.</dd>
1150
1151           <dt><code>internal</code></dt>
1152           <dd>A simulated network device that sends and receives traffic.  An
1153           internal interface whose <ref column="name"/> is the same as its
1154           bridge's <ref table="Open_vSwitch" column="name"/> is called the
1155           ``local interface.''  It does not make sense to bond an internal
1156           interface, so the terms ``port'' and ``interface'' are often used
1157           imprecisely for internal interfaces.</dd>
1158
1159           <dt><code>tap</code></dt>
1160           <dd>A TUN/TAP device managed by Open vSwitch.</dd>
1161
1162           <dt><code>gre</code></dt>
1163           <dd>
1164             An Ethernet over RFC 2890 Generic Routing Encapsulation over IPv4
1165             tunnel.  See <ref group="Tunnel Options"/> for information on
1166             configuring GRE tunnels.
1167           </dd>
1168
1169           <dt><code>ipsec_gre</code></dt>
1170           <dd>
1171             An Ethernet over RFC 2890 Generic Routing Encapsulation over IPv4
1172             IPsec tunnel.
1173           </dd>
1174
1175           <dt><code>capwap</code></dt>
1176           <dd>
1177             An Ethernet tunnel over the UDP transport portion of CAPWAP (RFC
1178             5415).  This allows interoperability with certain switches that do
1179             not support GRE.  Only the tunneling component of the protocol is
1180             implemented.  UDP ports 58881 and 58882 are used as the source and
1181             destination ports respectively.  CAPWAP is currently supported only
1182             with the Linux kernel datapath with kernel version 2.6.26 or later.
1183           </dd>
1184
1185           <dt><code>patch</code></dt>
1186           <dd>
1187             A pair of virtual devices that act as a patch cable.
1188           </dd>
1189
1190           <dt><code>null</code></dt>
1191           <dd>An ignored interface.</dd>
1192         </dl>
1193       </column>
1194     </group>
1195
1196     <group title="Tunnel Options">
1197       <p>
1198         These options apply to interfaces with <ref column="type"/> of
1199         <code>gre</code>, <code>ipsec_gre</code>, and <code>capwap</code>.
1200       </p>
1201
1202       <p>
1203         Each tunnel must be uniquely identified by the combination of <ref
1204         column="type"/>, <ref column="options" key="remote_ip"/>, <ref
1205         column="options" key="local_ip"/>, and <ref column="options"
1206         key="in_key"/>.  If two ports are defined that are the same except one
1207         has an optional identifier and the other does not, the more specific
1208         one is matched first.  <ref column="options" key="in_key"/> is
1209         considered more specific than <ref column="options" key="local_ip"/> if
1210         a port defines one and another port defines the other.
1211       </p>
1212
1213       <column name="options" key="remote_ip">
1214         <p>
1215           Required.  The tunnel endpoint.  Unicast and multicast endpoints are
1216           both supported.
1217         </p>
1218
1219         <p>
1220           When a multicast endpoint is specified, a routing table lookup occurs
1221           only when the tunnel is created.  Following a routing change, delete
1222           and then re-create the tunnel to force a new routing table lookup.
1223         </p>
1224       </column>
1225
1226       <column name="options" key="local_ip">
1227         Optional.  The destination IP that received packets must match.
1228         Default is to match all addresses.  Must be omitted when <ref
1229         column="options" key="remote_ip"/> is a multicast address.
1230       </column>
1231
1232       <column name="options" key="in_key">
1233         <p>Optional.  The key that received packets must contain, one of:</p>
1234
1235         <ul>
1236           <li>
1237             <code>0</code>.  The tunnel receives packets with no key or with a
1238             key of 0.  This is equivalent to specifying no <ref column="options"
1239             key="in_key"/> at all.
1240           </li>
1241           <li>
1242             A positive 32-bit (for GRE) or 64-bit (for CAPWAP) number.  The
1243             tunnel receives only packets with the specified key.
1244           </li>
1245           <li>
1246             The word <code>flow</code>.  The tunnel accepts packets with any
1247             key.  The key will be placed in the <code>tun_id</code> field for
1248             matching in the flow table.  The <code>ovs-ofctl</code> manual page
1249             contains additional information about matching fields in OpenFlow
1250             flows.
1251           </li>
1252         </ul>
1253
1254         <p>
1255         </p>
1256       </column>
1257
1258       <column name="options" key="out_key">
1259         <p>Optional.  The key to be set on outgoing packets, one of:</p>
1260
1261         <ul>
1262           <li>
1263             <code>0</code>.  Packets sent through the tunnel will have no key.
1264             This is equivalent to specifying no <ref column="options"
1265             key="out_key"/> at all.
1266           </li>
1267           <li>
1268             A positive 32-bit (for GRE) or 64-bit (for CAPWAP) number.  Packets
1269             sent through the tunnel will have the specified key.
1270           </li>
1271           <li>
1272             The word <code>flow</code>.  Packets sent through the tunnel will
1273             have the key set using the <code>set_tunnel</code> Nicira OpenFlow
1274             vendor extension (0 is used in the absence of an action).  The
1275             <code>ovs-ofctl</code> manual page contains additional information
1276             about the Nicira OpenFlow vendor extensions.
1277           </li>
1278         </ul>
1279       </column>
1280
1281       <column name="options" key="key">
1282         Optional.  Shorthand to set <code>in_key</code> and
1283         <code>out_key</code> at the same time.
1284       </column>
1285
1286       <column name="options" key="tos">
1287         Optional.  The value of the ToS bits to be set on the encapsulating
1288         packet.  It may also be the word <code>inherit</code>, in which case
1289         the ToS will be copied from the inner packet if it is IPv4 or IPv6
1290         (otherwise it will be 0).  The ECN fields are always inherited.
1291         Default is 0.
1292       </column>
1293
1294       <column name="options" key="ttl">
1295         Optional.  The TTL to be set on the encapsulating packet.  It may also
1296         be the word <code>inherit</code>, in which case the TTL will be copied
1297         from the inner packet if it is IPv4 or IPv6 (otherwise it will be the
1298         system default, typically 64).  Default is the system default TTL.
1299       </column>
1300
1301       <column name="options" key="df_inherit" type='{"type": "boolean"}'>
1302         Optional.  If enabled, the Don't Fragment bit will be copied from the
1303         inner IP headers (those of the encapsulated traffic) to the outer
1304         (tunnel) headers.  Default is disabled; set to <code>true</code> to
1305         enable.
1306       </column>
1307
1308       <column name="options" key="df_default"
1309               type='{"type": "boolean"}'>
1310         Optional.  If enabled, the Don't Fragment bit will be set by default on
1311         tunnel headers if the <code>df_inherit</code> option is not set, or if
1312         the encapsulated packet is not IP.  Default is enabled; set to
1313         <code>false</code> to disable.
1314       </column>
1315
1316       <column name="options" key="pmtud" type='{"type": "boolean"}'>
1317         Optional.  Enable tunnel path MTU discovery.  If enabled ``ICMP
1318         Destination Unreachable - Fragmentation Needed'' messages will be
1319         generated for IPv4 packets with the DF bit set and IPv6 packets above
1320         the minimum MTU if the packet size exceeds the path MTU minus the size
1321         of the tunnel headers.  Note that this option causes behavior that is
1322         typically reserved for routers and therefore is not entirely in
1323         compliance with the IEEE 802.1D specification for bridges.  Default is
1324         enabled; set to <code>false</code> to disable.
1325       </column>
1326
1327       <group title="Tunnel Options: gre only">
1328         <p>
1329           Only <code>gre</code> interfaces support these options.
1330         </p>
1331
1332         <column name="options" key="header_cache" type='{"type": "boolean"}'>
1333           Enable caching of tunnel headers and the output path.  This can lead
1334           to a significant performance increase without changing behavior.  In
1335           general it should not be necessary to adjust this setting.  However,
1336           the caching can bypass certain components of the IP stack (such as
1337           <code>iptables</code>) and it may be useful to disable it if these
1338           features are required or as a debugging measure.  Default is enabled,
1339           set to <code>false</code> to disable.
1340         </column>
1341       </group>
1342
1343       <group title="Tunnel Options: gre and ipsec_gre only">
1344         <p>
1345           Only <code>gre</code> and <code>ipsec_gre</code> interfaces support
1346           these options.
1347         </p>
1348
1349         <column name="options" key="csum" type='{"type": "boolean"}'>
1350           <p>
1351             Optional.  Compute GRE checksums on outgoing packets.  Default is
1352             disabled, set to <code>true</code> to enable.  Checksums present on
1353             incoming packets will be validated regardless of this setting.
1354           </p>
1355
1356           <p>
1357             GRE checksums impose a significant performance penalty because they
1358             cover the entire packet.  The encapsulated L3, L4, and L7 packet
1359             contents typically have their own checksums, so this additional
1360             checksum only adds value for the GRE and encapsulated L2 headers.
1361           </p>
1362
1363           <p>
1364             This option is supported for <code>ipsec_gre</code>, but not useful
1365             because GRE checksums are weaker than, and redundant with, IPsec
1366             payload authentication.
1367           </p>
1368         </column>
1369       </group>
1370
1371       <group title="Tunnel Options: ipsec_gre only">
1372         <p>
1373           Only <code>ipsec_gre</code> interfaces support these options.
1374         </p>
1375
1376         <column name="options" key="peer_cert">
1377           Required for certificate authentication.  A string containing the
1378           peer's certificate in PEM format.  Additionally the host's
1379           certificate must be specified with the <code>certificate</code>
1380           option.
1381         </column>
1382
1383         <column name="options" key="certificate">
1384           Required for certificate authentication.  The name of a PEM file
1385           containing a certificate that will be presented to the peer during
1386           authentication.
1387         </column>
1388
1389         <column name="options" key="private_key">
1390           Optional for certificate authentication.  The name of a PEM file
1391           containing the private key associated with <code>certificate</code>.
1392           If <code>certificate</code> contains the private key, this option may
1393           be omitted.
1394         </column>
1395
1396         <column name="options" key="psk">
1397           Required for pre-shared key authentication.  Specifies a pre-shared
1398           key for authentication that must be identical on both sides of the
1399           tunnel.
1400         </column>
1401       </group>
1402     </group>
1403
1404     <group title="Patch Options">
1405       <p>
1406         Only <code>patch</code> interfaces support these options.
1407       </p>
1408
1409       <column name="options" key="peer">
1410         The <ref column="name"/> of the <ref table="Interface"/> for the other
1411         side of the patch.  The named <ref table="Interface"/>'s own
1412         <code>peer</code> option must specify this <ref table="Interface"/>'s
1413         name.  That is, the two patch interfaces must have reversed <ref
1414         column="name"/> and <code>peer</code> values.
1415       </column>
1416     </group>
1417
1418     <group title="Interface Status">
1419       <p>
1420         Status information about interfaces attached to bridges, updated every
1421         5 seconds.  Not all interfaces have all of these properties; virtual
1422         interfaces don't have a link speed, for example.  Non-applicable
1423         columns will have empty values.
1424       </p>
1425       <column name="admin_state">
1426         <p>
1427           The administrative state of the physical network link.
1428         </p>
1429       </column>
1430
1431       <column name="link_state">
1432         <p>
1433           The observed state of the physical network link.  This is ordinarily
1434           the link's carrier status.  If the interface's <ref table="Port"/> is
1435           a bond configured for miimon monitoring, it is instead the network
1436           link's miimon status.
1437         </p>
1438       </column>
1439
1440       <column name="link_resets">
1441         <p>
1442           The number of times Open vSwitch has observed the
1443           <ref column="link_state"/> of this <ref table="Interface"/> change.
1444         </p>
1445       </column>
1446
1447       <column name="link_speed">
1448         <p>
1449           The negotiated speed of the physical network link.
1450           Valid values are positive integers greater than 0.
1451         </p>
1452       </column>
1453
1454       <column name="duplex">
1455         <p>
1456           The duplex mode of the physical network link.
1457         </p>
1458       </column>
1459
1460       <column name="mtu">
1461         <p>
1462           The MTU (maximum transmission unit); i.e. the largest
1463           amount of data that can fit into a single Ethernet frame.
1464           The standard Ethernet MTU is 1500 bytes.  Some physical media
1465           and many kinds of virtual interfaces can be configured with
1466           higher MTUs.
1467         </p>
1468         <p>
1469           This column will be empty for an interface that does not
1470           have an MTU as, for example, some kinds of tunnels do not.
1471         </p>
1472       </column>
1473
1474       <column name="lacp_current">
1475         Boolean value indicating LACP status for this interface.  If true, this
1476         interface has current LACP information about its LACP partner.  This
1477         information may be used to monitor the health of interfaces in a LACP
1478         enabled port.  This column will be empty if LACP is not enabled.
1479       </column>
1480
1481       <column name="status">
1482         Key-value pairs that report port status.  Supported status values are
1483         <ref column="type"/>-dependent; some interfaces may not have a valid
1484         <ref column="status" key="driver_name"/>, for example.
1485       </column>
1486
1487       <column name="status" key="driver_name">
1488         The name of the device driver controlling the network adapter.
1489       </column>
1490
1491       <column name="status" key="driver_version">
1492         The version string of the device driver controlling the network
1493         adapter.
1494       </column>
1495
1496       <column name="status" key="firmware_version">
1497         The version string of the network adapter's firmware, if available.
1498       </column>
1499
1500       <column name="status" key="source_ip">
1501         The source IP address used for an IPv4 tunnel end-point, such as
1502         <code>gre</code> or <code>capwap</code>.
1503       </column>
1504
1505       <column name="status" key="tunnel_egress_iface">
1506         Egress interface for tunnels.  Currently only relevant for GRE and
1507         CAPWAP tunnels.  On Linux systems, this column will show the name of
1508         the interface which is responsible for routing traffic destined for the
1509         configured <ref column="options" key="remote_ip"/>.  This could be an
1510         internal interface such as a bridge port.
1511       </column>
1512
1513       <column name="status" key="tunnel_egress_iface_carrier"
1514               type='{"type": "string", "enum": ["set", ["down", "up"]]}'>
1515         Whether carrier is detected on <ref column="status"
1516         key="tunnel_egress_iface"/>.
1517       </column>
1518     </group>
1519
1520     <group title="Statistics">
1521       <p>
1522         Key-value pairs that report interface statistics.  The current
1523         implementation updates these counters periodically.  Future
1524         implementations may update them when an interface is created, when they
1525         are queried (e.g. using an OVSDB <code>select</code> operation), and
1526         just before an interface is deleted due to virtual interface hot-unplug
1527         or VM shutdown, and perhaps at other times, but not on any regular
1528         periodic basis.
1529       </p>
1530       <p>
1531         These are the same statistics reported by OpenFlow in its <code>struct
1532         ofp_port_stats</code> structure.  If an interface does not support a
1533         given statistic, then that pair is omitted.
1534       </p>
1535       <group title="Statistics: Successful transmit and receive counters">
1536         <column name="statistics" key="rx_packets">
1537           Number of received packets.
1538         </column>
1539         <column name="statistics" key="rx_bytes">
1540           Number of received bytes.
1541         </column>
1542         <column name="statistics" key="tx_packets">
1543           Number of transmitted packets.
1544         </column>
1545         <column name="statistics" key="tx_bytes">
1546           Number of transmitted bytes.
1547         </column>
1548       </group>
1549       <group title="Statistics: Receive errors">
1550         <column name="statistics" key="rx_dropped">
1551           Number of packets dropped by RX.
1552         </column>
1553         <column name="statistics" key="rx_frame_err">
1554           Number of frame alignment errors.
1555         </column>
1556         <column name="statistics" key="rx_over_err">
1557           Number of packets with RX overrun.
1558         </column>
1559         <column name="statistics" key="rx_crc_err">
1560           Number of CRC errors.
1561         </column>
1562         <column name="statistics" key="rx_errors">
1563           Total number of receive errors, greater than or equal to the sum of
1564           the above.
1565         </column>
1566       </group>
1567       <group title="Statistics: Transmit errors">
1568         <column name="statistics" key="tx_dropped">
1569           Number of packets dropped by TX.
1570         </column>
1571         <column name="statistics" key="collisions">
1572           Number of collisions.
1573         </column>
1574         <column name="statistics" key="tx_errors">
1575           Total number of transmit errors, greater than or equal to the sum of
1576           the above.
1577         </column>
1578       </group>
1579     </group>
1580
1581     <group title="Ingress Policing">
1582       <p>
1583         These settings control ingress policing for packets received on this
1584         interface.  On a physical interface, this limits the rate at which
1585         traffic is allowed into the system from the outside; on a virtual
1586         interface (one connected to a virtual machine), this limits the rate at
1587         which the VM is able to transmit.
1588       </p>
1589       <p>
1590         Policing is a simple form of quality-of-service that simply drops
1591         packets received in excess of the configured rate.  Due to its
1592         simplicity, policing is usually less accurate and less effective than
1593         egress QoS (which is configured using the <ref table="QoS"/> and <ref
1594         table="Queue"/> tables).
1595       </p>
1596       <p>
1597         Policing is currently implemented only on Linux.  The Linux
1598         implementation uses a simple ``token bucket'' approach:
1599       </p>
1600       <ul>
1601         <li>
1602           The size of the bucket corresponds to <ref
1603           column="ingress_policing_burst"/>.  Initially the bucket is full.
1604         </li>
1605         <li>
1606           Whenever a packet is received, its size (converted to tokens) is
1607           compared to the number of tokens currently in the bucket.  If the
1608           required number of tokens are available, they are removed and the
1609           packet is forwarded.  Otherwise, the packet is dropped.
1610         </li>
1611         <li>
1612           Whenever it is not full, the bucket is refilled with tokens at the
1613           rate specified by <ref column="ingress_policing_rate"/>.
1614         </li>
1615       </ul>
1616       <p>
1617         Policing interacts badly with some network protocols, and especially
1618         with fragmented IP packets.  Suppose that there is enough network
1619         activity to keep the bucket nearly empty all the time.  Then this token
1620         bucket algorithm will forward a single packet every so often, with the
1621         period depending on packet size and on the configured rate.  All of the
1622         fragments of an IP packets are normally transmitted back-to-back, as a
1623         group.  In such a situation, therefore, only one of these fragments
1624         will be forwarded and the rest will be dropped.  IP does not provide
1625         any way for the intended recipient to ask for only the remaining
1626         fragments.  In such a case there are two likely possibilities for what
1627         will happen next: either all of the fragments will eventually be
1628         retransmitted (as TCP will do), in which case the same problem will
1629         recur, or the sender will not realize that its packet has been dropped
1630         and data will simply be lost (as some UDP-based protocols will do).
1631         Either way, it is possible that no forward progress will ever occur.
1632       </p>
1633       <column name="ingress_policing_rate">
1634         <p>
1635           Maximum rate for data received on this interface, in kbps.  Data
1636           received faster than this rate is dropped.  Set to <code>0</code>
1637           (the default) to disable policing.
1638         </p>
1639       </column>
1640
1641       <column name="ingress_policing_burst">
1642         <p>Maximum burst size for data received on this interface, in kb.  The
1643         default burst size if set to <code>0</code> is 1000 kb.  This value
1644         has no effect if <ref column="ingress_policing_rate"/>
1645         is <code>0</code>.</p>
1646         <p>
1647           Specifying a larger burst size lets the algorithm be more forgiving,
1648           which is important for protocols like TCP that react severely to
1649           dropped packets.  The burst size should be at least the size of the
1650           interface's MTU.  Specifying a value that is numerically at least as
1651           large as 10% of <ref column="ingress_policing_rate"/> helps TCP come
1652           closer to achieving the full rate.
1653         </p>
1654       </column>
1655     </group>
1656
1657     <group title="Connectivity Fault Management">
1658       <p>
1659         802.1ag Connectivity Fault Management (CFM) allows a group of
1660         Maintenance Points (MPs) called a Maintenance Association (MA) to
1661         detect connectivity problems with each other.  MPs within a MA should
1662         have complete and exclusive interconnectivity.  This is verified by
1663         occasionally broadcasting Continuity Check Messages (CCMs) at a
1664         configurable transmission interval.
1665       </p>
1666
1667       <p>
1668         According to the 802.1ag specification, each Maintenance Point should
1669         be configured out-of-band with a list of Remote Maintenance Points it
1670         should have connectivity to.  Open vSwitch differs from the
1671         specification in this area.  It simply assumes the link is faulted if
1672         no Remote Maintenance Points are reachable, and considers it not
1673         faulted otherwise.
1674       </p>
1675
1676       <column name="cfm_mpid">
1677         A Maintenance Point ID (MPID) uniquely identifies each endpoint within
1678         a Maintenance Association.  The MPID is used to identify this endpoint
1679         to other Maintenance Points in the MA.  Each end of a link being
1680         monitored should have a different MPID.  Must be configured to enable
1681         CFM on this <ref table="Interface"/>.
1682       </column>
1683
1684       <column name="cfm_fault">
1685         <p>
1686           Indicates a connectivity fault triggered by an inability to receive
1687           heartbeats from any remote endpoint.  When a fault is triggered on
1688           <ref table="Interface"/>s participating in bonds, they will be
1689           disabled.
1690         </p>
1691         <p>
1692           Faults can be triggered for several reasons.  Most importantly they
1693           are triggered when no CCMs are received for a period of 3.5 times the
1694           transmission interval. Faults are also triggered when any CCMs
1695           indicate that a Remote Maintenance Point is not receiving CCMs but
1696           able to send them.  Finally, a fault is triggered if a CCM is
1697           received which indicates unexpected configuration.  Notably, this
1698           case arises when a CCM is received which advertises the local MPID.
1699         </p>
1700       </column>
1701
1702       <column name="cfm_remote_mpids">
1703         When CFM is properly configured, Open vSwitch will occasionally
1704         receive CCM broadcasts.  These broadcasts contain the MPID of the
1705         sending Maintenance Point.  The list of MPIDs from which this
1706         <ref table="Interface"/> is receiving broadcasts from is regularly
1707         collected and written to this column.
1708       </column>
1709
1710       <column name="other_config" key="cfm_interval"
1711               type='{"type": "integer"}'>
1712         The interval, in milliseconds, between transmissions of CFM heartbeats.
1713         Three missed heartbeat receptions indicate a connectivity fault.
1714         Defaults to 1000.
1715       </column>
1716
1717       <column name="other_config" key="cfm_extended"
1718               type='{"type": "boolean"}'>
1719         When <code>true</code>, the CFM module operates in extended mode. This
1720         causes it to use a nonstandard destination address to avoid conflicting
1721         with compliant implementations which may be running concurrently on the
1722         network. Furthermore, extended mode increases the accuracy of the
1723         <code>cfm_interval</code> configuration parameter by breaking wire
1724         compatibility with 802.1ag compliant implementations.  Defaults to
1725         <code>false</code>.
1726       </column>
1727       <column name="other_config" key="cfm_opstate"
1728               type='{"type": "string", "enum": ["set", ["down", "up"]]}'>
1729         When <code>down</code>, the CFM module marks all CCMs it generates as
1730         operationally down without triggering a fault.  This allows remote
1731         maintenance points to choose not to forward traffic to the
1732         <ref table="Interface"/> on which this CFM module is running.
1733         Currently, in Open vSwitch, the opdown bit of CCMs affects
1734         <ref table="Interface"/>s participating in bonds, and the bundle
1735         OpenFlow action. This setting is ignored when CFM is not in extended
1736         mode.  Defaults to <code>up</code>.
1737       </column>
1738
1739       <column name="other_config" key="cfm_ccm_vlan"
1740         type='{"type": "integer", "minInteger": 1, "maxInteger": 4095}'>
1741         When set, the CFM module will apply a VLAN tag to all CCMs it generates
1742         with the given value.
1743       </column>
1744
1745       <column name="other_config" key="cfm_ccm_pcp"
1746         type='{"type": "integer", "minInteger": 1, "maxInteger": 7}'>
1747         When set, the CFM module will apply a VLAN tag to all CCMs it generates
1748         with the given PCP value.  The VLAN ID of the tag is governed by the
1749         value of <ref column="other_config" key="cfm_ccm_vlan"/>. If
1750         <ref column="other_config" key="cfm_ccm_vlan"/> is unset, a VLAN ID of
1751         zero is used.
1752       </column>
1753
1754     </group>
1755
1756     <group title="Bonding Configuration">
1757       <column name="other_config" key="bond-stable-id"
1758               type='{"type": "integer", "minInteger": 1}'>
1759         Used in <code>stable</code> bond mode to make slave
1760         selection decisions.  Allocating <ref column="other_config"
1761         key="bond-stable-id"/> values consistently across interfaces
1762         participating in a bond will guarantee consistent slave selection
1763         decisions across <code>ovs-vswitchd</code> instances when using
1764         <code>stable</code> bonding mode.
1765       </column>
1766
1767       <column name="other_config" key="lacp-port-id"
1768               type='{"type": "integer", "minInteger": 1, "maxInteger": 65535}'>
1769         The LACP port ID of this <ref table="Interface"/>.  Port IDs are
1770         used in LACP negotiations to identify individual ports
1771         participating in a bond.
1772       </column>
1773
1774       <column name="other_config" key="lacp-port-priority"
1775               type='{"type": "integer", "minInteger": 1, "maxInteger": 65535}'>
1776         The LACP port priority of this <ref table="Interface"/>.  In LACP
1777         negotiations <ref table="Interface"/>s with numerically lower
1778         priorities are preferred for aggregation.
1779       </column>
1780
1781       <column name="other_config" key="lacp-aggregation-key"
1782               type='{"type": "integer", "minInteger": 1, "maxInteger": 65535}'>
1783         The LACP aggregation key of this <ref table="Interface"/>.  <ref
1784         table="Interface"/>s with different aggregation keys may not be active
1785         within a given <ref table="Port"/> at the same time.
1786       </column>
1787     </group>
1788
1789     <group title="Virtual Machine Identifiers">
1790       <p>
1791         These key-value pairs specifically apply to an interface that
1792         represents a virtual Ethernet interface connected to a virtual
1793         machine.  These key-value pairs should not be present for other types
1794         of interfaces.  Keys whose names end in <code>-uuid</code> have
1795         values that uniquely identify the entity in question.  For a Citrix
1796         XenServer hypervisor, these values are UUIDs in RFC 4122 format.
1797         Other hypervisors may use other formats.
1798       </p>
1799
1800       <column name="external_ids" key="attached-mac">
1801         The MAC address programmed into the ``virtual hardware'' for this
1802         interface, in the form
1803         <var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>:<var>xx</var>.
1804         For Citrix XenServer, this is the value of the <code>MAC</code> field
1805         in the VIF record for this interface.
1806       </column>
1807
1808       <column name="external_ids" key="iface-id">
1809         A system-unique identifier for the interface.  On XenServer, this will
1810         commonly be the same as <ref column="external_ids" key="xs-vif-uuid"/>.
1811       </column>
1812
1813       <column name="external_ids" key="xs-vif-uuid">
1814         The virtual interface associated with this interface.
1815       </column>
1816
1817       <column name="external_ids" key="xs-network-uuid">
1818         The virtual network to which this interface is attached.
1819       </column>
1820
1821       <column name="external_ids" key="xs-vm-uuid">
1822         The VM to which this interface belongs.
1823       </column>
1824     </group>
1825
1826     <group title="VLAN Splinters">
1827       <p>
1828         The ``VLAN splinters'' feature increases Open vSwitch compatibility
1829         with buggy network drivers in old versions of Linux that do not
1830         properly support VLANs when VLAN devices are not used, at some cost
1831         in memory and performance.
1832       </p>
1833
1834       <p>
1835         When VLAN splinters are enabled on a particular interface, Open vSwitch
1836         creates a VLAN device for each in-use VLAN.  For sending traffic tagged
1837         with a VLAN on the interface, it substitutes the VLAN device.  Traffic
1838         received on the VLAN device is treated as if it had been received on
1839         the interface on the particular VLAN.
1840       </p>
1841
1842       <p>
1843         VLAN splinters consider a VLAN to be in use if:
1844       </p>
1845
1846       <ul>
1847         <li>
1848           The VLAN is the <ref table="Port" column="tag"/> value in any <ref
1849           table="Port"/> record.
1850         </li>
1851
1852         <li>
1853           The VLAN is listed within the <ref table="Port" column="trunks"/>
1854           column of the <ref table="Port"/> record of an interface on which
1855           VLAN splinters are enabled.
1856
1857           An empty <ref table="Port" column="trunks"/> does not influence the
1858           in-use VLANs: creating 4,096 VLAN devices is impractical because it
1859           will exceed the current 1,024 port per datapath limit.
1860         </li>
1861
1862         <li>
1863           An OpenFlow flow within any bridge matches the VLAN.
1864         </li>
1865       </ul>
1866
1867       <p>
1868         The same set of in-use VLANs applies to every interface on which VLAN
1869         splinters are enabled.  That is, the set is not chosen separately for
1870         each interface but selected once as the union of all in-use VLANs based
1871         on the rules above.
1872       </p>
1873
1874       <p>
1875         It does not make sense to enable VLAN splinters on an interface for an
1876         access port, or on an interface that is not a physical port.
1877       </p>
1878
1879       <p>
1880         VLAN splinters are deprecated.  When broken device drivers are no
1881         longer in widespread use, we will delete this feature.
1882       </p>
1883
1884       <column name="other_config" key="enable-vlan-splinters"
1885               type='{"type": "boolean"}'>
1886         <p>
1887           Set to <code>true</code> to enable VLAN splinters on this interface.
1888           Defaults to <code>false</code>.
1889         </p>
1890
1891         <p>
1892           VLAN splinters increase kernel and userspace memory overhead, so do
1893           not use them unless they are needed.
1894         </p>
1895       </column>
1896     </group>
1897
1898     <group title="Common Columns">
1899       The overall purpose of these columns is described under <code>Common
1900       Columns</code> at the beginning of this document.
1901
1902       <column name="other_config"/>
1903       <column name="external_ids"/>
1904     </group>
1905   </table>
1906
1907   <table name="Flow_Table" title="OpenFlow table configuration">
1908     <p>Configuration for a particular OpenFlow table.</p>
1909
1910     <column name="name">
1911       The table's name.  Set this column to change the name that controllers
1912       will receive when they request table statistics, e.g. <code>ovs-ofctl
1913       dump-tables</code>.  The name does not affect switch behavior.
1914     </column>
1915
1916     <column name="flow_limit">
1917       If set, limits the number of flows that may be added to the table.  Open
1918       vSwitch may limit the number of flows in a table for other reasons,
1919       e.g. due to hardware limitations or for resource availability or
1920       performance reasons.
1921     </column>
1922
1923     <column name="overflow_policy">
1924       <p>
1925         Controls the switch's behavior when an OpenFlow flow table modification
1926         request would add flows in excess of <ref column="flow_limit"/>.  The
1927         supported values are:
1928       </p>
1929
1930       <dl>
1931         <dt><code>refuse</code></dt>
1932         <dd>
1933           Refuse to add the flow or flows.  This is also the default policy
1934           when <ref column="overflow_policy"/> is unset.
1935         </dd>
1936
1937         <dt><code>evict</code></dt>
1938         <dd>
1939           Delete the flow that will expire soonest.  See <ref column="groups"/>
1940           for details.
1941         </dd>
1942       </dl>
1943     </column>
1944
1945     <column name="groups">
1946       <p>
1947         When <ref column="overflow_policy"/> is <code>evict</code>, this
1948         controls how flows are chosen for eviction when the flow table would
1949         otherwise exceed <ref column="flow_limit"/> flows.  Its value is a set
1950         of NXM fields or sub-fields, each of which takes one of the forms
1951         <code><var>field</var>[]</code> or
1952         <code><var>field</var>[<var>start</var>..<var>end</var>]</code>,
1953         e.g. <code>NXM_OF_IN_PORT[]</code>.  Please see
1954         <code>nicira-ext.h</code> for a complete list of NXM field names.
1955       </p>
1956
1957       <p>
1958         When a flow must be evicted due to overflow, the flow to evict is
1959         chosen through an approximation of the following algorithm:
1960       </p>
1961
1962       <ol>
1963         <li>
1964           Divide the flows in the table into groups based on the values of the
1965           specified fields or subfields, so that all of the flows in a given
1966           group have the same values for those fields.  If a flow does not
1967           specify a given field, that field's value is treated as 0.
1968         </li>
1969
1970         <li>
1971           Consider the flows in the largest group, that is, the group that
1972           contains the greatest number of flows.  If two or more groups all
1973           have the same largest number of flows, consider the flows in all of
1974           those groups.
1975         </li>
1976
1977         <li>
1978           Among the flows under consideration, choose the flow that expires
1979           soonest for eviction.
1980         </li>
1981       </ol>
1982
1983       <p>
1984         The eviction process only considers flows that have an idle timeout or
1985         a hard timeout.  That is, eviction never deletes permanent flows.
1986         (Permanent flows do count against <ref column="flow_limit"/>.
1987       </p>
1988
1989       <p>
1990         Open vSwitch ignores any invalid or unknown field specifications.
1991       </p>
1992
1993       <p>
1994         When <ref column="overflow_policy"/> is not <code>evict</code>, this
1995         column has no effect.
1996       </p>
1997     </column>
1998   </table>
1999
2000   <table name="QoS" title="Quality of Service configuration">
2001     <p>Quality of Service (QoS) configuration for each Port that
2002     references it.</p>
2003
2004     <column name="type">
2005       <p>The type of QoS to implement.  The <ref table="Open_vSwitch"
2006       column="capabilities"/> column in the <ref table="Open_vSwitch"/> table
2007       identifies the types that a switch actually supports.  The currently
2008       defined types are listed below:</p>
2009       <dl>
2010         <dt><code>linux-htb</code></dt>
2011         <dd>
2012           Linux ``hierarchy token bucket'' classifier.  See tc-htb(8) (also at
2013           <code>http://linux.die.net/man/8/tc-htb</code>) and the HTB manual
2014           (<code>http://luxik.cdi.cz/~devik/qos/htb/manual/userg.htm</code>)
2015           for information on how this classifier works and how to configure it.
2016         </dd>
2017       </dl>
2018       <dl>
2019         <dt><code>linux-hfsc</code></dt>
2020         <dd>
2021           Linux "Hierarchical Fair Service Curve" classifier.
2022           See <code>http://linux-ip.net/articles/hfsc.en/</code> for
2023           information on how this classifier works.
2024         </dd>
2025       </dl>
2026     </column>
2027
2028     <column name="queues">
2029       <p>A map from queue numbers to <ref table="Queue"/> records.  The
2030       supported range of queue numbers depend on <ref column="type"/>.  The
2031       queue numbers are the same as the <code>queue_id</code> used in
2032       OpenFlow in <code>struct ofp_action_enqueue</code> and other
2033       structures.  Queue 0 is used by OpenFlow output actions that do not
2034       specify a specific queue.</p>
2035     </column>
2036
2037     <group title="Configuration for linux-htb and linux-hfsc">
2038       <p>
2039         The <code>linux-htb</code> and <code>linux-hfsc</code> classes support
2040         the following key-value pair:
2041       </p>
2042
2043       <column name="other_config" key="max-rate" type='{"type": "integer"}'>
2044         Maximum rate shared by all queued traffic, in bit/s.  Optional.  If not
2045         specified, for physical interfaces, the default is the link rate.  For
2046         other interfaces or if the link rate cannot be determined, the default
2047         is currently 100 Mbps.
2048       </column>
2049     </group>
2050
2051     <group title="Common Columns">
2052       The overall purpose of these columns is described under <code>Common
2053       Columns</code> at the beginning of this document.
2054
2055       <column name="other_config"/>
2056       <column name="external_ids"/>
2057     </group>
2058   </table>
2059
2060   <table name="Queue" title="QoS output queue.">
2061     <p>A configuration for a port output queue, used in configuring Quality of
2062     Service (QoS) features.  May be referenced by <ref column="queues"
2063     table="QoS"/> column in <ref table="QoS"/> table.</p>
2064
2065     <column name="dscp">
2066       If set, Open vSwitch will mark all traffic egressing this
2067       <ref table="Queue"/> with the given DSCP bits.  Traffic egressing the
2068       default <ref table="Queue"/> is only marked if it was explicitly selected
2069       as the <ref table="Queue"/> at the time the packet was output.  If unset,
2070       the DSCP bits of traffic egressing this <ref table="Queue"/> will remain
2071       unchanged.
2072     </column>
2073
2074     <group title="Configuration for linux-htb QoS">
2075       <p>
2076         <ref table="QoS"/> <ref table="QoS" column="type"/>
2077         <code>linux-htb</code> may use <code>queue_id</code>s less than 61440.
2078         It has the following key-value pairs defined.
2079       </p>
2080
2081       <column name="other_config" key="min-rate"
2082               type='{"type": "integer", "minInteger": 1}'>
2083         Minimum guaranteed bandwidth, in bit/s.
2084       </column>
2085
2086       <column name="other_config" key="max-rate"
2087               type='{"type": "integer", "minInteger": 1}'>
2088         Maximum allowed bandwidth, in bit/s.  Optional.  If specified, the
2089         queue's rate will not be allowed to exceed the specified value, even
2090         if excess bandwidth is available.  If unspecified, defaults to no
2091         limit.
2092       </column>
2093
2094       <column name="other_config" key="burst"
2095               type='{"type": "integer", "minInteger": 1}'>
2096         Burst size, in bits.  This is the maximum amount of ``credits'' that a
2097         queue can accumulate while it is idle.  Optional.  Details of the
2098         <code>linux-htb</code> implementation require a minimum burst size, so
2099         a too-small <code>burst</code> will be silently ignored.
2100       </column>
2101
2102       <column name="other_config" key="priority"
2103               type='{"type": "integer", "minInteger": 0, "maxInteger": 4294967295}'>
2104         A queue with a smaller <code>priority</code> will receive all the
2105         excess bandwidth that it can use before a queue with a larger value
2106         receives any.  Specific priority values are unimportant; only relative
2107         ordering matters.  Defaults to 0 if unspecified.
2108       </column>
2109     </group>
2110
2111     <group title="Configuration for linux-hfsc QoS">
2112       <p>
2113         <ref table="QoS"/> <ref table="QoS" column="type"/>
2114         <code>linux-hfsc</code> may use <code>queue_id</code>s less than 61440.
2115         It has the following key-value pairs defined.
2116       </p>
2117
2118       <column name="other_config" key="min-rate"
2119               type='{"type": "integer", "minInteger": 1}'>
2120         Minimum guaranteed bandwidth, in bit/s.
2121       </column>
2122
2123       <column name="other_config" key="max-rate"
2124               type='{"type": "integer", "minInteger": 1}'>
2125         Maximum allowed bandwidth, in bit/s.  Optional.  If specified, the
2126         queue's rate will not be allowed to exceed the specified value, even if
2127         excess bandwidth is available.  If unspecified, defaults to no
2128         limit.
2129       </column>
2130     </group>
2131
2132     <group title="Common Columns">
2133       The overall purpose of these columns is described under <code>Common
2134       Columns</code> at the beginning of this document.
2135
2136       <column name="other_config"/>
2137       <column name="external_ids"/>
2138     </group>
2139   </table>
2140
2141   <table name="Mirror" title="Port mirroring.">
2142     <p>A port mirror within a <ref table="Bridge"/>.</p>
2143     <p>A port mirror configures a bridge to send selected frames to special
2144     ``mirrored'' ports, in addition to their normal destinations.  Mirroring
2145     traffic may also be referred to as SPAN or RSPAN, depending on how
2146     the mirrored traffic is sent.</p>
2147
2148     <column name="name">
2149       Arbitrary identifier for the <ref table="Mirror"/>.
2150     </column>
2151
2152     <group title="Selecting Packets for Mirroring">
2153       <p>
2154         To be selected for mirroring, a given packet must enter or leave the
2155         bridge through a selected port and it must also be in one of the
2156         selected VLANs.
2157       </p>
2158
2159       <column name="select_all">
2160         If true, every packet arriving or departing on any port is
2161         selected for mirroring.
2162       </column>
2163
2164       <column name="select_dst_port">
2165         Ports on which departing packets are selected for mirroring.
2166       </column>
2167
2168       <column name="select_src_port">
2169         Ports on which arriving packets are selected for mirroring.
2170       </column>
2171
2172       <column name="select_vlan">
2173         VLANs on which packets are selected for mirroring.  An empty set
2174         selects packets on all VLANs.
2175       </column>
2176     </group>
2177
2178     <group title="Mirroring Destination Configuration">
2179       <p>
2180         These columns are mutually exclusive.  Exactly one of them must be
2181         nonempty.
2182       </p>
2183
2184       <column name="output_port">
2185         <p>Output port for selected packets, if nonempty.</p>
2186         <p>Specifying a port for mirror output reserves that port exclusively
2187         for mirroring.  No frames other than those selected for mirroring
2188         via this column
2189         will be forwarded to the port, and any frames received on the port
2190         will be discarded.</p>
2191         <p>
2192           The output port may be any kind of port supported by Open vSwitch.
2193           It may be, for example, a physical port (sometimes called SPAN) or a
2194           GRE tunnel.
2195         </p>
2196       </column>
2197
2198       <column name="output_vlan">
2199         <p>Output VLAN for selected packets, if nonempty.</p>
2200         <p>The frames will be sent out all ports that trunk
2201         <ref column="output_vlan"/>, as well as any ports with implicit VLAN
2202         <ref column="output_vlan"/>.  When a mirrored frame is sent out a
2203         trunk port, the frame's VLAN tag will be set to
2204         <ref column="output_vlan"/>, replacing any existing tag; when it is
2205         sent out an implicit VLAN port, the frame will not be tagged.  This
2206         type of mirroring is sometimes called RSPAN.</p>
2207         <p>
2208           The following destination MAC addresses will not be mirrored to a
2209           VLAN to avoid confusing switches that interpret the protocols that
2210           they represent:
2211         </p>
2212         <dl>
2213           <dt><code>01:80:c2:00:00:00</code></dt>
2214           <dd>IEEE 802.1D Spanning Tree Protocol (STP).</dd>
2215
2216           <dt><code>01:80:c2:00:00:01</code></dt>
2217           <dd>IEEE Pause frame.</dd>
2218
2219           <dt><code>01:80:c2:00:00:0<var>x</var></code></dt>
2220           <dd>Other reserved protocols.</dd>
2221
2222           <dt><code>01:00:0c:cc:cc:cc</code></dt>
2223           <dd>
2224             Cisco Discovery Protocol (CDP), VLAN Trunking Protocol (VTP),
2225             Dynamic Trunking Protocol (DTP), Port Aggregation Protocol (PAgP),
2226             and others.
2227           </dd>
2228
2229           <dt><code>01:00:0c:cc:cc:cd</code></dt>
2230           <dd>Cisco Shared Spanning Tree Protocol PVSTP+.</dd>
2231
2232           <dt><code>01:00:0c:cd:cd:cd</code></dt>
2233           <dd>Cisco STP Uplink Fast.</dd>
2234
2235           <dt><code>01:00:0c:00:00:00</code></dt>
2236           <dd>Cisco Inter Switch Link.</dd>
2237         </dl>
2238         <p><em>Please note:</em> Mirroring to a VLAN can disrupt a network that
2239         contains unmanaged switches.  Consider an unmanaged physical switch
2240         with two ports: port 1, connected to an end host, and port 2,
2241         connected to an Open vSwitch configured to mirror received packets
2242         into VLAN 123 on port 2.  Suppose that the end host sends a packet on
2243         port 1 that the physical switch forwards to port 2.  The Open vSwitch
2244         forwards this packet to its destination and then reflects it back on
2245         port 2 in VLAN 123.  This reflected packet causes the unmanaged
2246         physical switch to replace the MAC learning table entry, which
2247         correctly pointed to port 1, with one that incorrectly points to port
2248         2.  Afterward, the physical switch will direct packets destined for
2249         the end host to the Open vSwitch on port 2, instead of to the end
2250         host on port 1, disrupting connectivity.  If mirroring to a VLAN is
2251         desired in this scenario, then the physical switch must be replaced
2252         by one that learns Ethernet addresses on a per-VLAN basis.  In
2253         addition, learning should be disabled on the VLAN containing mirrored
2254         traffic. If this is not done then intermediate switches will learn
2255         the MAC address of each end host from the mirrored traffic.  If
2256         packets being sent to that end host are also mirrored, then they will
2257         be dropped since the switch will attempt to send them out the input
2258         port. Disabling learning for the VLAN will cause the switch to
2259         correctly send the packet out all ports configured for that VLAN.  If
2260         Open vSwitch is being used as an intermediate switch, learning can be
2261         disabled by adding the mirrored VLAN to <ref column="flood_vlans"/>
2262         in the appropriate <ref table="Bridge"/> table or tables.</p>
2263         <p>
2264           Mirroring to a GRE tunnel has fewer caveats than mirroring to a
2265           VLAN and should generally be preferred.
2266         </p>
2267       </column>
2268     </group>
2269
2270     <group title="Statistics: Mirror counters">
2271       <p>
2272         Key-value pairs that report mirror statistics.
2273       </p>
2274       <column name="statistics" key="tx_packets">
2275         Number of packets transmitted through this mirror.
2276       </column>
2277       <column name="statistics" key="tx_bytes">
2278         Number of bytes transmitted through this mirror.
2279       </column>
2280     </group>
2281
2282     <group title="Common Columns">
2283       The overall purpose of these columns is described under <code>Common
2284       Columns</code> at the beginning of this document.
2285
2286       <column name="external_ids"/>
2287     </group>
2288   </table>
2289
2290   <table name="Controller" title="OpenFlow controller configuration.">
2291     <p>An OpenFlow controller.</p>
2292
2293     <p>
2294       Open vSwitch supports two kinds of OpenFlow controllers:
2295     </p>
2296
2297     <dl>
2298       <dt>Primary controllers</dt>
2299       <dd>
2300         <p>
2301           This is the kind of controller envisioned by the OpenFlow 1.0
2302           specification.  Usually, a primary controller implements a network
2303           policy by taking charge of the switch's flow table.
2304         </p>
2305
2306         <p>
2307           Open vSwitch initiates and maintains persistent connections to
2308           primary controllers, retrying the connection each time it fails or
2309           drops.  The <ref table="Bridge" column="fail_mode"/> column in the
2310           <ref table="Bridge"/> table applies to primary controllers.
2311         </p>
2312
2313         <p>
2314           Open vSwitch permits a bridge to have any number of primary
2315           controllers.  When multiple controllers are configured, Open
2316           vSwitch connects to all of them simultaneously.  Because
2317           OpenFlow 1.0 does not specify how multiple controllers
2318           coordinate in interacting with a single switch, more than
2319           one primary controller should be specified only if the
2320           controllers are themselves designed to coordinate with each
2321           other.  (The Nicira-defined <code>NXT_ROLE</code> OpenFlow
2322           vendor extension may be useful for this.)
2323         </p>
2324       </dd>
2325       <dt>Service controllers</dt>
2326       <dd>
2327         <p>
2328           These kinds of OpenFlow controller connections are intended for
2329           occasional support and maintenance use, e.g. with
2330           <code>ovs-ofctl</code>.  Usually a service controller connects only
2331           briefly to inspect or modify some of a switch's state.
2332         </p>
2333
2334         <p>
2335           Open vSwitch listens for incoming connections from service
2336           controllers.  The service controllers initiate and, if necessary,
2337           maintain the connections from their end.  The <ref table="Bridge"
2338           column="fail_mode"/> column in the <ref table="Bridge"/> table does
2339           not apply to service controllers.
2340         </p>
2341
2342         <p>
2343           Open vSwitch supports configuring any number of service controllers.
2344         </p>
2345       </dd>
2346     </dl>
2347
2348     <p>
2349       The <ref column="target"/> determines the type of controller.
2350     </p>
2351
2352     <group title="Core Features">
2353       <column name="target">
2354         <p>Connection method for controller.</p>
2355         <p>
2356           The following connection methods are currently supported for primary
2357           controllers:
2358         </p>
2359         <dl>
2360           <dt><code>ssl:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
2361           <dd>
2362             <p>The specified SSL <var>port</var> (default: 6633) on the host at
2363             the given <var>ip</var>, which must be expressed as an IP address
2364             (not a DNS name).  The <ref table="Open_vSwitch" column="ssl"/>
2365             column in the <ref table="Open_vSwitch"/> table must point to a
2366             valid SSL configuration when this form is used.</p>
2367             <p>SSL support is an optional feature that is not always built as
2368             part of Open vSwitch.</p>
2369           </dd>
2370           <dt><code>tcp:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
2371           <dd>The specified TCP <var>port</var> (default: 6633) on the host at
2372           the given <var>ip</var>, which must be expressed as an IP address
2373           (not a DNS name).</dd>
2374         </dl>
2375         <p>
2376           The following connection methods are currently supported for service
2377           controllers:
2378         </p>
2379         <dl>
2380           <dt><code>pssl:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
2381           <dd>
2382             <p>
2383               Listens for SSL connections on the specified TCP <var>port</var>
2384               (default: 6633).  If <var>ip</var>, which must be expressed as an
2385               IP address (not a DNS name), is specified, then connections are
2386               restricted to the specified local IP address.
2387             </p>
2388             <p>
2389               The <ref table="Open_vSwitch" column="ssl"/> column in the <ref
2390               table="Open_vSwitch"/> table must point to a valid SSL
2391               configuration when this form is used.
2392             </p>
2393             <p>SSL support is an optional feature that is not always built as
2394             part of Open vSwitch.</p>
2395           </dd>
2396           <dt><code>ptcp:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
2397           <dd>
2398             Listens for connections on the specified TCP <var>port</var>
2399             (default: 6633).  If <var>ip</var>, which must be expressed as an
2400             IP address (not a DNS name), is specified, then connections are
2401             restricted to the specified local IP address.
2402           </dd>
2403         </dl>
2404         <p>When multiple controllers are configured for a single bridge, the
2405         <ref column="target"/> values must be unique.  Duplicate
2406         <ref column="target"/> values yield unspecified results.</p>
2407       </column>
2408
2409       <column name="connection_mode">
2410         <p>If it is specified, this setting must be one of the following
2411         strings that describes how Open vSwitch contacts this OpenFlow
2412         controller over the network:</p>
2413
2414         <dl>
2415           <dt><code>in-band</code></dt>
2416           <dd>In this mode, this controller's OpenFlow traffic travels over the
2417           bridge associated with the controller.  With this setting, Open
2418           vSwitch allows traffic to and from the controller regardless of the
2419           contents of the OpenFlow flow table.  (Otherwise, Open vSwitch
2420           would never be able to connect to the controller, because it did
2421           not have a flow to enable it.)  This is the most common connection
2422           mode because it is not necessary to maintain two independent
2423           networks.</dd>
2424           <dt><code>out-of-band</code></dt>
2425           <dd>In this mode, OpenFlow traffic uses a control network separate
2426           from the bridge associated with this controller, that is, the
2427           bridge does not use any of its own network devices to communicate
2428           with the controller.  The control network must be configured
2429           separately, before or after <code>ovs-vswitchd</code> is started.
2430           </dd>
2431         </dl>
2432
2433         <p>If not specified, the default is implementation-specific.</p>
2434       </column>
2435     </group>
2436
2437     <group title="Controller Failure Detection and Handling">
2438       <column name="max_backoff">
2439         Maximum number of milliseconds to wait between connection attempts.
2440         Default is implementation-specific.
2441       </column>
2442
2443       <column name="inactivity_probe">
2444         Maximum number of milliseconds of idle time on connection to
2445         controller before sending an inactivity probe message.  If Open
2446         vSwitch does not communicate with the controller for the specified
2447         number of seconds, it will send a probe.  If a response is not
2448         received for the same additional amount of time, Open vSwitch
2449         assumes the connection has been broken and attempts to reconnect.
2450         Default is implementation-specific.  A value of 0 disables
2451         inactivity probes.
2452       </column>
2453     </group>
2454
2455     <group title="OpenFlow Rate Limiting">
2456       <column name="controller_rate_limit">
2457         <p>
2458           The maximum rate at which the switch will forward packets to the
2459           OpenFlow controller, in packets per second.  This feature prevents a
2460           single bridge from overwhelming the controller.  If not specified,
2461           the default is implementation-specific.
2462         </p>
2463
2464         <p>
2465           In addition, when a high rate triggers rate-limiting, Open vSwitch
2466           queues controller packets for each port and transmits them to the
2467           controller at the configured rate.  The <ref
2468           column="controller_burst_limit"/> value limits the number of queued
2469           packets.  Ports on a bridge share the packet queue fairly.
2470         </p>
2471
2472         <p>
2473           Open vSwitch maintains two such packet rate-limiters per bridge: one
2474           for packets sent up to the controller because they do not correspond
2475           to any flow, and the other for packets sent up to the controller by
2476           request through flow actions. When both rate-limiters are filled with
2477           packets, the actual rate that packets are sent to the controller is
2478           up to twice the specified rate.
2479         </p>
2480       </column>
2481
2482       <column name="controller_burst_limit">
2483         In conjunction with <ref column="controller_rate_limit"/>,
2484         the maximum number of unused packet credits that the bridge will
2485         allow to accumulate, in packets.  If not specified, the default
2486         is implementation-specific.
2487       </column>
2488     </group>
2489
2490     <group title="Additional In-Band Configuration">
2491       <p>These values are considered only in in-band control mode (see
2492       <ref column="connection_mode"/>).</p>
2493
2494       <p>When multiple controllers are configured on a single bridge, there
2495       should be only one set of unique values in these columns.  If different
2496       values are set for these columns in different controllers, the effect
2497       is unspecified.</p>
2498
2499       <column name="local_ip">
2500         The IP address to configure on the local port,
2501         e.g. <code>192.168.0.123</code>.  If this value is unset, then
2502         <ref column="local_netmask"/> and <ref column="local_gateway"/> are
2503         ignored.
2504       </column>
2505
2506       <column name="local_netmask">
2507         The IP netmask to configure on the local port,
2508         e.g. <code>255.255.255.0</code>.  If <ref column="local_ip"/> is set
2509         but this value is unset, then the default is chosen based on whether
2510         the IP address is class A, B, or C.
2511       </column>
2512
2513       <column name="local_gateway">
2514         The IP address of the gateway to configure on the local port, as a
2515         string, e.g. <code>192.168.0.1</code>.  Leave this column unset if
2516         this network has no gateway.
2517       </column>
2518     </group>
2519
2520     <group title="Controller Status">
2521       <column name="is_connected">
2522         <code>true</code> if currently connected to this controller,
2523         <code>false</code> otherwise.
2524       </column>
2525
2526       <column name="role"
2527               type='{"type": "string", "enum": ["set", ["other", "master", "slave"]]}'>
2528         <p>The level of authority this controller has on the associated
2529         bridge. Possible values are:</p>
2530         <dl>
2531           <dt><code>other</code></dt>
2532           <dd>Allows the controller access to all OpenFlow features.</dd>
2533           <dt><code>master</code></dt>
2534           <dd>Equivalent to <code>other</code>, except that there may be at
2535           most one master controller at a time.  When a controller configures
2536           itself as <code>master</code>, any existing master is demoted to
2537           the <code>slave</code>role.</dd>
2538           <dt><code>slave</code></dt>
2539           <dd>Allows the controller read-only access to OpenFlow features.
2540           Attempts to modify the flow table will be rejected with an
2541           error.  Slave controllers do not receive OFPT_PACKET_IN or
2542           OFPT_FLOW_REMOVED messages, but they do receive OFPT_PORT_STATUS
2543           messages.</dd>
2544         </dl>
2545       </column>
2546
2547       <column name="status" key="last_error">
2548         A human-readable description of the last error on the connection
2549         to the controller; i.e. <code>strerror(errno)</code>.  This key
2550         will exist only if an error has occurred.
2551       </column>
2552
2553       <column name="status" key="state"
2554               type='{"type": "string", "enum": ["set", ["VOID", "BACKOFF", "CONNECTING", "ACTIVE", "IDLE"]]}'>
2555         <p>
2556           The state of the connection to the controller:
2557         </p>
2558         <dl>
2559           <dt><code>VOID</code></dt>
2560           <dd>Connection is disabled.</dd>
2561
2562           <dt><code>BACKOFF</code></dt>
2563           <dd>Attempting to reconnect at an increasing period.</dd>
2564
2565           <dt><code>CONNECTING</code></dt>
2566           <dd>Attempting to connect.</dd>
2567
2568           <dt><code>ACTIVE</code></dt>
2569           <dd>Connected, remote host responsive.</dd>
2570
2571           <dt><code>IDLE</code></dt>
2572           <dd>Connection is idle.  Waiting for response to keep-alive.</dd>
2573         </dl>
2574         <p>
2575           These values may change in the future.  They are provided only for
2576           human consumption.
2577         </p>
2578       </column>
2579
2580       <column name="status" key="sec_since_connect"
2581               type='{"type": "integer", "minInteger": 0}'>
2582         The amount of time since this controller last successfully connected to
2583         the switch (in seconds).  Value is empty if controller has never
2584         successfully connected.
2585       </column>
2586
2587       <column name="status" key="sec_since_disconnect"
2588               type='{"type": "integer", "minInteger": 1}'>
2589         The amount of time since this controller last disconnected from
2590         the switch (in seconds). Value is empty if controller has never
2591         disconnected.
2592       </column>
2593     </group>
2594
2595     <group title="Common Columns">
2596       The overall purpose of these columns is described under <code>Common
2597       Columns</code> at the beginning of this document.
2598
2599       <column name="external_ids"/>
2600     </group>
2601   </table>
2602
2603   <table name="Manager" title="OVSDB management connection.">
2604     <p>
2605       Configuration for a database connection to an Open vSwitch database
2606       (OVSDB) client.
2607     </p>
2608
2609     <p>
2610       This table primarily configures the Open vSwitch database
2611       (<code>ovsdb-server</code>), not the Open vSwitch switch
2612       (<code>ovs-vswitchd</code>).  The switch does read the table to determine
2613       what connections should be treated as in-band.
2614     </p>
2615
2616     <p>
2617       The Open vSwitch database server can initiate and maintain active
2618       connections to remote clients.  It can also listen for database
2619       connections.
2620     </p>
2621
2622     <group title="Core Features">
2623       <column name="target">
2624         <p>Connection method for managers.</p>
2625         <p>
2626           The following connection methods are currently supported:
2627         </p>
2628         <dl>
2629           <dt><code>ssl:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
2630           <dd>
2631             <p>
2632               The specified SSL <var>port</var> (default: 6632) on the host at
2633               the given <var>ip</var>, which must be expressed as an IP address
2634               (not a DNS name).  The <ref table="Open_vSwitch" column="ssl"/>
2635               column in the <ref table="Open_vSwitch"/> table must point to a
2636               valid SSL configuration when this form is used.
2637             </p>
2638             <p>
2639               SSL support is an optional feature that is not always built as
2640               part of Open vSwitch.
2641             </p>
2642           </dd>
2643
2644           <dt><code>tcp:<var>ip</var></code>[<code>:<var>port</var></code>]</dt>
2645           <dd>
2646             The specified TCP <var>port</var> (default: 6632) on the host at
2647             the given <var>ip</var>, which must be expressed as an IP address
2648             (not a DNS name).
2649           </dd>
2650           <dt><code>pssl:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
2651           <dd>
2652             <p>
2653               Listens for SSL connections on the specified TCP <var>port</var>
2654               (default: 6632).  If <var>ip</var>, which must be expressed as an
2655               IP address (not a DNS name), is specified, then connections are
2656               restricted to the specified local IP address.
2657             </p>
2658             <p>
2659               The <ref table="Open_vSwitch" column="ssl"/> column in the <ref
2660               table="Open_vSwitch"/> table must point to a valid SSL
2661               configuration when this form is used.
2662             </p>
2663             <p>
2664               SSL support is an optional feature that is not always built as
2665               part of Open vSwitch.
2666             </p>
2667           </dd>
2668           <dt><code>ptcp:</code>[<var>port</var>][<code>:<var>ip</var></code>]</dt>
2669           <dd>
2670             Listens for connections on the specified TCP <var>port</var>
2671             (default: 6632).  If <var>ip</var>, which must be expressed as an
2672             IP address (not a DNS name), is specified, then connections are
2673             restricted to the specified local IP address.
2674           </dd>
2675         </dl>
2676         <p>When multiple managers are configured, the <ref column="target"/>
2677         values must be unique.  Duplicate <ref column="target"/> values yield
2678         unspecified results.</p>
2679       </column>
2680
2681       <column name="connection_mode">
2682         <p>
2683           If it is specified, this setting must be one of the following strings
2684           that describes how Open vSwitch contacts this OVSDB client over the
2685           network:
2686         </p>
2687
2688         <dl>
2689           <dt><code>in-band</code></dt>
2690           <dd>
2691             In this mode, this connection's traffic travels over a bridge
2692             managed by Open vSwitch.  With this setting, Open vSwitch allows
2693             traffic to and from the client regardless of the contents of the
2694             OpenFlow flow table.  (Otherwise, Open vSwitch would never be able
2695             to connect to the client, because it did not have a flow to enable
2696             it.)  This is the most common connection mode because it is not
2697             necessary to maintain two independent networks.
2698           </dd>
2699           <dt><code>out-of-band</code></dt>
2700           <dd>
2701             In this mode, the client's traffic uses a control network separate
2702             from that managed by Open vSwitch, that is, Open vSwitch does not
2703             use any of its own network devices to communicate with the client.
2704             The control network must be configured separately, before or after
2705             <code>ovs-vswitchd</code> is started.
2706           </dd>
2707         </dl>
2708
2709         <p>
2710           If not specified, the default is implementation-specific.
2711         </p>
2712       </column>
2713     </group>
2714
2715     <group title="Client Failure Detection and Handling">
2716       <column name="max_backoff">
2717         Maximum number of milliseconds to wait between connection attempts.
2718         Default is implementation-specific.
2719       </column>
2720
2721       <column name="inactivity_probe">
2722         Maximum number of milliseconds of idle time on connection to the client
2723         before sending an inactivity probe message.  If Open vSwitch does not
2724         communicate with the client for the specified number of seconds, it
2725         will send a probe.  If a response is not received for the same
2726         additional amount of time, Open vSwitch assumes the connection has been
2727         broken and attempts to reconnect.  Default is implementation-specific.
2728         A value of 0 disables inactivity probes.
2729       </column>
2730     </group>
2731
2732     <group title="Status">
2733       <column name="is_connected">
2734         <code>true</code> if currently connected to this manager,
2735         <code>false</code> otherwise.
2736       </column>
2737
2738       <column name="status" key="last_error">
2739         A human-readable description of the last error on the connection
2740         to the manager; i.e. <code>strerror(errno)</code>.  This key
2741         will exist only if an error has occurred.
2742       </column>
2743
2744       <column name="status" key="state"
2745               type='{"type": "string", "enum": ["set", ["VOID", "BACKOFF", "CONNECTING", "ACTIVE", "IDLE"]]}'>
2746         <p>
2747           The state of the connection to the manager:
2748         </p>
2749         <dl>
2750           <dt><code>VOID</code></dt>
2751           <dd>Connection is disabled.</dd>
2752
2753           <dt><code>BACKOFF</code></dt>
2754           <dd>Attempting to reconnect at an increasing period.</dd>
2755
2756           <dt><code>CONNECTING</code></dt>
2757           <dd>Attempting to connect.</dd>
2758
2759           <dt><code>ACTIVE</code></dt>
2760           <dd>Connected, remote host responsive.</dd>
2761
2762           <dt><code>IDLE</code></dt>
2763           <dd>Connection is idle.  Waiting for response to keep-alive.</dd>
2764         </dl>
2765         <p>
2766           These values may change in the future.  They are provided only for
2767           human consumption.
2768         </p>
2769       </column>
2770
2771       <column name="status" key="sec_since_connect"
2772               type='{"type": "integer", "minInteger": 0}'>
2773         The amount of time since this manager last successfully connected
2774         to the database (in seconds). Value is empty if manager has never
2775         successfully connected.
2776       </column>
2777
2778       <column name="status" key="sec_since_disconnect"
2779               type='{"type": "integer", "minInteger": 0}'>
2780         The amount of time since this manager last disconnected from the
2781         database (in seconds). Value is empty if manager has never
2782         disconnected.
2783       </column>
2784
2785       <column name="status" key="locks_held">
2786         Space-separated list of the names of OVSDB locks that the connection
2787         holds.  Omitted if the connection does not hold any locks.
2788       </column>
2789
2790       <column name="status" key="locks_waiting">
2791         Space-separated list of the names of OVSDB locks that the connection is
2792         currently waiting to acquire.  Omitted if the connection is not waiting
2793         for any locks.
2794       </column>
2795
2796       <column name="status" key="locks_lost">
2797         Space-separated list of the names of OVSDB locks that the connection
2798         has had stolen by another OVSDB client.  Omitted if no locks have been
2799         stolen from this connection.
2800       </column>
2801
2802       <column name="status" key="n_connections"
2803               type='{"type": "integer", "minInteger": 2}'>
2804         <p>
2805           When <ref column="target"/> specifies a connection method that
2806           listens for inbound connections (e.g. <code>ptcp:</code> or
2807           <code>pssl:</code>) and more than one connection is actually active,
2808           the value is the number of active connections.  Otherwise, this
2809           key-value pair is omitted.
2810         </p>
2811         <p>
2812           When multiple connections are active, status columns and key-value
2813           pairs (other than this one) report the status of one arbitrarily
2814           chosen connection.
2815         </p>
2816       </column>
2817     </group>
2818
2819     <group title="Common Columns">
2820       The overall purpose of these columns is described under <code>Common
2821       Columns</code> at the beginning of this document.
2822
2823       <column name="external_ids"/>
2824     </group>
2825   </table>
2826
2827   <table name="NetFlow">
2828     A NetFlow target.  NetFlow is a protocol that exports a number of
2829     details about terminating IP flows, such as the principals involved
2830     and duration.
2831
2832     <column name="targets">
2833       NetFlow targets in the form
2834       <code><var>ip</var>:<var>port</var></code>.  The <var>ip</var>
2835       must be specified numerically, not as a DNS name.
2836     </column>
2837
2838     <column name="engine_id">
2839       Engine ID to use in NetFlow messages.  Defaults to datapath index
2840       if not specified.
2841     </column>
2842
2843     <column name="engine_type">
2844       Engine type to use in NetFlow messages.  Defaults to datapath
2845       index if not specified.
2846     </column>
2847
2848     <column name="active_timeout">
2849       The interval at which NetFlow records are sent for flows that are
2850       still active, in seconds.  A value of <code>0</code> requests the
2851       default timeout (currently 600 seconds); a value of <code>-1</code>
2852       disables active timeouts.
2853     </column>
2854
2855     <column name="add_id_to_interface">
2856       <p>If this column's value is <code>false</code>, the ingress and egress
2857       interface fields of NetFlow flow records are derived from OpenFlow port
2858       numbers.  When it is <code>true</code>, the 7 most significant bits of
2859       these fields will be replaced by the least significant 7 bits of the
2860       engine id.  This is useful because many NetFlow collectors do not
2861       expect multiple switches to be sending messages from the same host, so
2862       they do not store the engine information which could be used to
2863       disambiguate the traffic.</p>
2864       <p>When this option is enabled, a maximum of 508 ports are supported.</p>
2865     </column>
2866
2867     <group title="Common Columns">
2868       The overall purpose of these columns is described under <code>Common
2869       Columns</code> at the beginning of this document.
2870
2871       <column name="external_ids"/>
2872     </group>
2873   </table>
2874
2875   <table name="SSL">
2876     SSL configuration for an Open_vSwitch.
2877
2878     <column name="private_key">
2879       Name of a PEM file containing the private key used as the switch's
2880       identity for SSL connections to the controller.
2881     </column>
2882
2883     <column name="certificate">
2884       Name of a PEM file containing a certificate, signed by the
2885       certificate authority (CA) used by the controller and manager,
2886       that certifies the switch's private key, identifying a trustworthy
2887       switch.
2888     </column>
2889
2890     <column name="ca_cert">
2891       Name of a PEM file containing the CA certificate used to verify
2892       that the switch is connected to a trustworthy controller.
2893     </column>
2894
2895     <column name="bootstrap_ca_cert">
2896       If set to <code>true</code>, then Open vSwitch will attempt to
2897       obtain the CA certificate from the controller on its first SSL
2898       connection and save it to the named PEM file. If it is successful,
2899       it will immediately drop the connection and reconnect, and from then
2900       on all SSL connections must be authenticated by a certificate signed
2901       by the CA certificate thus obtained.  <em>This option exposes the
2902       SSL connection to a man-in-the-middle attack obtaining the initial
2903       CA certificate.</em>  It may still be useful for bootstrapping.
2904     </column>
2905
2906     <group title="Common Columns">
2907       The overall purpose of these columns is described under <code>Common
2908       Columns</code> at the beginning of this document.
2909
2910       <column name="external_ids"/>
2911     </group>
2912   </table>
2913
2914   <table name="sFlow">
2915     <p>An sFlow(R) target.  sFlow is a protocol for remote monitoring
2916     of switches.</p>
2917
2918     <column name="agent">
2919       Name of the network device whose IP address should be reported as the
2920       ``agent address'' to collectors.  If not specified, the agent device is
2921       figured from the first target address and the routing table.  If the
2922       routing table does not contain a route to the target, the IP address
2923       defaults to the <ref table="Controller" column="local_ip"/> in the
2924       collector's <ref table="Controller"/>.  If an agent IP address cannot be
2925       determined any of these ways, sFlow is disabled.
2926     </column>
2927
2928     <column name="header">
2929       Number of bytes of a sampled packet to send to the collector.
2930       If not specified, the default is 128 bytes.
2931     </column>
2932
2933     <column name="polling">
2934       Polling rate in seconds to send port statistics to the collector.
2935       If not specified, defaults to 30 seconds.
2936     </column>
2937
2938     <column name="sampling">
2939       Rate at which packets should be sampled and sent to the collector.
2940       If not specified, defaults to 400, which means one out of 400
2941       packets, on average, will be sent to the collector.
2942     </column>
2943
2944     <column name="targets">
2945       sFlow targets in the form
2946       <code><var>ip</var>:<var>port</var></code>.
2947     </column>
2948
2949     <group title="Common Columns">
2950       The overall purpose of these columns is described under <code>Common
2951       Columns</code> at the beginning of this document.
2952
2953       <column name="external_ids"/>
2954     </group>
2955   </table>
2956
2957   <table name="Capability">
2958     <p>Records in this table describe functionality supported by the hardware
2959     and software platform on which this Open vSwitch is based.  Clients
2960     should not modify this table.</p>
2961
2962     <p>A record in this table is meaningful only if it is referenced by the
2963     <ref table="Open_vSwitch" column="capabilities"/> column in the
2964     <ref table="Open_vSwitch"/> table.  The key used to reference it, called
2965     the record's ``category,'' determines the meanings of the
2966     <ref column="details"/> column.  The following general forms of
2967     categories are currently defined:</p>
2968
2969     <dl>
2970       <dt><code>qos-<var>type</var></code></dt>
2971       <dd><var>type</var> is supported as the value for
2972       <ref column="type" table="QoS"/> in the <ref table="QoS"/> table.
2973       </dd>
2974     </dl>
2975
2976     <column name="details">
2977       <p>Key-value pairs that describe capabilities.  The meaning of the pairs
2978       depends on the category key that the <ref table="Open_vSwitch"
2979       column="capabilities"/> column in the <ref table="Open_vSwitch"/> table
2980       uses to reference this record, as described above.</p>
2981
2982       <p>The presence of a record for category <code>qos-<var>type</var></code>
2983       indicates that the switch supports <var>type</var> as the value of
2984       the <ref table="QoS" column="type"/> column in the <ref table="QoS"/>
2985       table.  The following key-value pairs are defined to further describe
2986       QoS capabilities:</p>
2987
2988       <dl>
2989         <dt><code>n-queues</code></dt>
2990         <dd>Number of supported queues, as a positive integer.  Keys in the
2991         <ref table="QoS" column="queues"/> column for <ref table="QoS"/>
2992         records whose <ref table="QoS" column="type"/> value
2993         equals <var>type</var> must range between 0 and this value minus one,
2994         inclusive.</dd>
2995       </dl>
2996     </column>
2997   </table>
2998