2 ------------------------
3 - New %t and %T log escapes to identify the subprogram within a
4 cooperating group of processes or threads that emitted a log message.
5 The default log patterns now include this information.
7 - Allow bitwise masking for IPv6 flow label.
11 ------------------------
12 - New FAQ. Please send updates and additions!
13 - Authors of controllers, please read the new section titled "Action
14 Reproduction" in DESIGN, which describes an Open vSwitch change in
15 behavior in corner cases that may affect some controllers.
17 - A new test utility that can create L3 tunnel between two Open
18 vSwitches and detect connectivity issues.
20 - New --sort and --rsort options for "dump-flows" command.
21 - "mod-port" command can now control all OpenFlow config flags.
23 - Allow general bitwise masking for IPv4 and IPv6 addresses in
24 IPv4, IPv6, and ARP packets. (Previously, only CIDR masks
26 - Allow support for arbitrary Ethernet masks. (Previously, only
27 the multicast bit in the destination address could be individually
29 - New field OXM_OF_METADATA, to align with OpenFlow 1.1.
30 - The OFPST_QUEUE request now reports an error if a specified port or
31 queue does not exist, or for requests for a specific queue on all
32 ports, if the specified queue does not exist on any port. (Previous
33 versions generally reported an empty set of results.)
34 - New "flow monitor" feature to allow controllers to be notified of
35 flow table changes as they happen.
36 - Additional protocols are not mirrored and dropped when forward-bpdu is
37 false. For a full list, see the ovs-vswitchd.conf.db man page.
38 - Open vSwitch now sends RARP packets in situations where it previously
39 sent a custom protocol, making it consistent with behavior of QEMU and
41 - All Open vSwitch programs and log files now show timestamps in UTC,
42 instead the local timezone, by default.
46 ------------------------
47 - kernel modules are renamed. openvswitch_mod.ko is now
48 openvswitch.ko and brcompat_mod.ko is now brcompat.ko.
49 - Increased the number of NXM registers to 8.
50 - Added ability to configure dscp setting for manager and controller
51 connections. By default, these connections have a DSCP value of
52 Internetwork Control (0xc0).
53 - Added the granular link health statistics, 'cfm_health', to an
56 - Added support to mask nd_target for ICMPv6 neighbor discovery flows.
57 - Added support for OpenFlow 1.3 port description (OFPMP_PORT_DESC)
60 - Added the "dump-ports-desc" command to retrieve port
61 information using the new port description multipart messages.
63 - Added support for spawning ovs-test server from the client.
64 - Now ovs-test is able to automatically create test bridges and ports.
65 - "ovs-dpctl dump-flows" now prints observed TCP flags in TCP flows.
66 - The "coverage/log" command previously available through ovs-appctl
67 has been replaced by "coverage/show". The new command replies with
68 coverage counter values, instead of logging them.
72 ------------------------
73 - Allow OFPP_CONTROLLER as the in_port for packet-out messages.
77 ------------------------
78 *** Internal only release ***
80 - LACP bonds no longer fall back to balance-slb when negotiations fail.
81 Instead they drop traffic.
82 - The default bond_mode changed from SLB to active-backup, to protect
83 unsuspecting users from the significant risks of SLB bonds (which are
84 documented in vswitchd/INTERNALS).
85 - Load balancing can be disabled by setting the bond-rebalance-interval
88 - Added support for bitwise matching on TCP and UDP ports.
89 See ovs-ofctl(8) for more information.
90 - NXM flow dumps now include times elapsed toward idle and hard
92 - Added an OpenFlow extension NXT_SET_ASYNC_CONFIG that allows
93 controllers more precise control over which OpenFlow messages they
94 receive asynchronously.
95 - New "fin_timeout" action.
96 - Added "fin_timeout" support to "learn" action.
97 - New Nicira action NXAST_CONTROLLER that offers additional features
98 over output to OFPP_CONTROLLER.
99 - When QoS settings for an interface do not configure a default queue
100 (queue 0), Open vSwitch now uses a default configuration for that
101 queue, instead of dropping all packets as in previous versions.
103 - Logging to console and file will have UTC timestamp as a default for
104 all the daemons. An example of the default format is
105 2012-01-27T16:35:17Z. ovs-appctl can be used to change the default
107 - The syntax of commands and options to set log levels was simplified,
108 to make it easier to remember.
109 - New support for limiting the number of flows in an OpenFlow flow
110 table, with configurable policy for evicting flows upon
111 overflow. See the Flow_Table table in ovs-vswitch.conf.db(5)
112 for more information.
113 - New "enable-async-messages" column in the Controller table. If set to
114 false, OpenFlow connections to the controller will initially have all
115 asynchronous messages disabled, overriding normal OpenFlow behavior.
116 - ofproto-provider interface:
117 - "struct rule" has a new member "used" that ofproto implementations
118 should maintain by updating with ofproto_rule_update_used().
120 - The new option --timestamp causes the "monitor" command to print
121 a timestamp with every update.
122 - CFM module CCM broadcasts can now be tagged with an 802.1p priority.
126 ------------------------
128 - Added support for querying, modifying, and deleting flows
129 based on flow cookie when using NXM.
130 - Added new NXM_PACKET_IN format.
131 - Added new NXAST_DEC_TTL action.
133 - Added daemonization support to the monitor and snoop commands.
135 - The "find" command supports new set relational operators
136 {=}, {!=}, {<}, {>}, {<=}, and {>=}.
137 - ovsdb-tool now uses the typical database and schema installation
138 directories as defaults.
139 - The default MAC learning timeout has been increased from 60 seconds
140 to 300 seconds. The MAC learning timeout is now configurable.
144 ------------------------
145 - Compatible with Open vSwitch kernel module included in Linux 3.3.
146 - New "VLAN splinters" feature to work around buggy device drivers
147 in old Linux versions. (This feature is deprecated. When
148 broken device drivers are no longer in widespread use, we will
149 delete this feature.) See ovs-vswitchd.conf.db(5) for more
152 - Added ability to match on IPv6 flow label through NXM.
153 - Added ability to match on ECN bits in IPv4 and IPv6 through NXM.
154 - Added ability to match on TTL in IPv4 and IPv6 through NXM.
155 - Added ability to modify ECN bits in IPv4.
156 - Added ability to modify TTL in IPv4.
158 - Don't require the "normal" action to use mirrors. Traffic will
159 now be properly mirrored for any flows, regardless of their
161 - Track packet and byte statistics sent on mirrors.
162 - The sFlow implementation can now usually infer the correct agent
163 device instead of having to be told explicitly.
165 - New "fdb/flush" command to flush bridge's MAC learning table.
167 - A new distributed testing tool that allows one to diagnose performance
168 and connectivity issues. This tool currently is not included in RH or
170 - RHEL packaging now supports integration with Red Hat network scripts.
172 - Post 1.4.*, OVS will be changing the default bond mode from balance-slb
173 to active-backup. SLB bonds carry significant risks with them
174 (documented vswitchd/INTERNALS) which we want to prevent unsuspecting
175 users from running into. Users are advised to update any scripts or
176 configuration which may be negatively impacted by explicitly setting
177 the bond mode which they want to use.
181 ------------------------
183 - Added an OpenFlow extension which allows the "output" action to accept
185 - Added an OpenFlow extension for flexible learning.
186 - Bumped number of NXM registers from four to five.
188 - New "version" command to determine version of running daemon.
189 - If no argument is provided for "cfm/show", displays detailed
190 information about all interfaces with CFM enabled.
191 - If no argument is provided for "lacp/show", displays detailed
192 information about all ports with LACP enabled.
194 - New "set-if" command to modify a datapath port's configuration.
196 - The software switch now supports 255 OpenFlow tables, instead
197 of just one. By default, only table 0 is consulted, but the
198 new NXAST_RESUBMIT_TABLE action can look up in additional
199 tables. Tables 128 and above are reserved for use by the
200 switch itself; please use only tables 0 through 127.
201 - Add support for 802.1D spanning tree (STP).
202 - Fragment handling extensions:
203 - New OFPC_FRAG_NX_MATCH fragment handling mode, in which L4
204 fields are made available for matching in fragments with
206 - New NXM_NX_IP_FRAG match field for matching IP fragments (usable
207 via "ip_frag" in ovs-ofctl).
208 - New ovs-ofctl "get-frags" and "set-frags" commands to get and set
209 fragment handling policy.
210 - CAPWAP tunneling now supports an extension to transport a 64-bit key.
211 By default it remains compatible with the old version and other
212 standards-based implementations.
213 - Flow setups are now processed in a round-robin manner across ports
214 to prevent any single client from monopolizing the CPU and conducting
215 a denial of service attack.
216 - Added support for native VLAN tagging. A new "vlan_mode"
217 parameter can be set for "port". Possible values: "access",
218 "trunk", "native-tagged" and "native-untagged".
219 - test-openflowd has been removed. Please use ovs-vswitchd instead.
222 ------------------------
223 - New "ofproto" abstraction layer to ease porting to hardware
225 - Packaging for Red Hat Enterprise Linux 5.6 and 6.0.
226 - Datapath support for Linux kernels up to 3.0.
228 - New "bundle" and "bundle_load" action extensions.
230 - Implement table unique constraints.
231 - Support cooperative locking between callers.
233 - New "-s" option for "show" command prints packet and byte
234 counters for each port.
236 - New "--readd" option for "replace-flows".
238 - New "show" command to print an overview of configuration.
239 - New "comment" command to add remark that explains intentions.
240 - ovs-brcompatd has been rewritten to fix long-standing bugs.
241 - ovs-openflowd has been renamed test-openflowd and moved into the
242 tests directory. Its presence confused too many users. Please
243 use ovs-vswitchd instead.
244 - New ovs-benchmark utility to test flow setup performance.
245 - A new log level "off" has been added. Configuring a log facility
246 "off" prevents any messages from being logged to it. Previously,
247 "emer" was effectively "off" because no messages were ever logged at
248 level "emer". Now, errors that cause a process to exit are logged
250 - "configure" option --with-l26 has been renamed --with-linux, and
251 --with-l26-source has been renamed --with-linux-source. The old
252 names will be removed after the next release, so please update
254 - The "-2.6" suffix has been dropped from the datapath/linux-2.6 and
255 datapath/linux-2.6/compat-2.6 directories.
257 - Dropped support for "tun_id_from_cookie" OpenFlow extension.
258 Please use the extensible match extensions instead.
259 - Removed the Maintenance_Point and Monitor tables in an effort
260 to simplify 802.1ag configuration.
261 - Performance and scalability improvements
265 ------------------------
266 - Ability to define policies over IPv6
269 - Support for extensible match extensions to OpenFlow
271 - Support for HFSC qdisc.
272 - Queue used by in-band control can now be configured.
274 - Kernel<->userspace interface has been reworked and should be
275 close to a stable ABI now.
276 - "Port group" concept has been dropped.
277 - GRE over IPSEC tunnels
279 - New active backup bonding mode.
280 - New L4 hashing support when LACP is enabled.
281 - Source MAC hash now includes VLAN field also.
283 - Greatly improved handling of large flow tables
285 - "show" command now prints full vport configuration.
286 - "dump-groups" command removed since kernel support for
287 port groups was dropped.
289 - New commands for working with the new Managers table.
290 - "list" command enhanced with new formatting options and --columns
292 - "get" command now accepts new --id option.
293 - New "find" command.
295 - New "queue-stats" command for printing queue stats.
296 - New commands "replace-flows" and "diff-flows".
297 - Commands to add and remove flows can now read from files.
298 - New --flow-format option to enable or disable NXM.
299 - New --more option to increase OpenFlow message verbosity.
300 - Removed "tun-cookie" command, which is no longer useful.
301 - ovs-controller enhancements for testing various features.
302 - New ovs-vlan-test command for testing for Linux kernel driver VLAN
303 bugs. New ovs-vlan-bug-workaround command for enabling and
304 disabling a workaround for these driver bugs.
306 - "Resubmit" actions now update flow statistics.
307 - New "register" extension for use in matching and actions, via NXM.
308 - New "multipath" experimental action extension.
309 - New support for matching multicast Ethernet frames, via NXM.
310 - New extension for OpenFlow vendor error codes.
311 - New extension to set the QoS output queue without actually
312 sending to an output port.
313 - Open vSwitch now reports a single flow table, instead of
314 separate hash and wildcard tables. This better models the
315 current implementation.
316 - New experimental "note" action.
317 - New "ofproto/trace" ovs-appctl command and associated utilities
318 to ease debugging complex flow tables.
320 - Schema documentation now includes an entity-relationship diagram.
321 - The database is now garbage collected. In most tables,
322 unreferenced rows will be deleted automatically.
323 - Many tables now include statistics updated periodically by
324 ovs-vswitchd or ovsdb-server.
325 - Every table now has an "external-ids" column for use by OVS
327 - There is no default controller anymore. Each bridge must have its
328 controller individually specified.
329 - The "fail-mode" is now a property of a Bridge instead of a Controller.
330 - New versioning and checksum features.
331 - New Managers table and manager_options column in Open_vSwitch table
332 for specifying managers. The old "managers" column in the
333 Open_vSwitch table has been removed.
334 - Many "name" columns are now immutable.
336 - Dropped support for XenServer pre-5.6.100.
337 - Dropped support for Linux pre-2.6.18.
338 - Dropped controller discovery support.
339 - Dropped "ovs-ofctl status" and the OpenFlow extension that it used.
340 Statistics reporting in the database is a rough equivalent.
341 - Dropped the "corekeeper" package (now separate, at
342 http://openvswitch.org/cgi-bin/gitweb.cgi?p=corekeeper).
343 - Performance and scalability improvements
346 v1.1.0pre2 - 13 Sep 2010
347 ------------------------
350 v1.1.0pre1 - 31 Aug 2010
351 ------------------------
352 - OpenFlow 1.0 slicing (QoS) functionality
353 - Python bindings for configuration database (no write support)
354 - Performance and scalability improvements
359 - New "patch" interface type
364 - Configuration database with remote management
367 - Support for XenServer 5.5 and 5.6
368 - Performance and scalability improvements
371 v0.99.2 - 18 Feb 2010
372 ---------------------
375 v0.99.1 - 25 Jan 2010
376 ---------------------
377 - Add support for sFlow(R)
378 - Make headers compatible with C++
381 v0.99.0 - 14 Jan 2010
382 ---------------------
383 - User-space forwarding engine
386 v0.90.7 - 29 Nov 2009
387 ---------------------
388 - Add support for NetFlow active timeouts
395 v0.90.5 - 21 Sep 2009
396 ---------------------
397 - Generalize in-band control to more diverse network setups