2 ------------------------
4 - "mod-port" command can now control all OpenFlow config flags.
5 - Added support for arbitrary ethernet masks
9 ------------------------
10 - kernel modules are renamed. openvswitch_mod.ko is now
11 openvswitch.ko and brcompat_mod.ko is now brcompat.ko.
12 - Increased the number of NXM registers to 8.
13 - Added ability to configure dscp setting for manager and controller
14 connections. By default, these connections have a DSCP value of
15 Internetwork Control (0xc0).
16 - Added the granular link health statistics, 'cfm_health', to an
19 - Added support to mask nd_target for ICMPv6 neighbor discovery flows.
20 - Added support for OpenFlow 1.3 port description (OFPMP_PORT_DESC)
23 - Added the "dump-ports-desc" command to retrieve port
24 information using the new port description multipart messages.
26 - Added support for spawning ovs-test server from the client.
27 - Now ovs-test is able to automatically create test bridges and ports.
28 - "ovs-dpctl dump-flows" now prints observed TCP flags in TCP flows.
29 - The "coverage/log" command previously available through ovs-appctl
30 has been replaced by "coverage/show". The new command replies with
31 coverage counter values, instead of logging them.
35 ------------------------
37 - LACP bonds no longer fall back to balance-slb when negotiations fail.
38 Instead they drop traffic.
39 - The default bond_mode changed from SLB to active-backup, to protect
40 unsuspecting users from the significant risks of SLB bonds (which are
41 documented in vswitchd/INTERNALS).
42 - Load balancing can be disabled by setting the bond-rebalance-interval
45 - Added support for bitwise matching on TCP and UDP ports.
46 See ovs-ofctl(8) for more information.
47 - NXM flow dumps now include times elapsed toward idle and hard
49 - Added an OpenFlow extension NXT_SET_ASYNC_CONFIG that allows
50 controllers more precise control over which OpenFlow messages they
51 receive asynchronously.
52 - New "fin_timeout" action.
53 - Added "fin_timeout" support to "learn" action.
54 - New Nicira action NXAST_CONTROLLER that offers additional features
55 over output to OFPP_CONTROLLER.
56 - The default MAC learning timeout has been increased from 60 seconds
57 to 300 seconds. The MAC learning timeout is now configurable.
58 - When QoS settings for an interface do not configure a default queue
59 (queue 0), Open vSwitch now uses a default configuration for that
60 queue, instead of dropping all packets as in previous versions.
62 - Logging to console and file will have UTC timestamp as a default for
63 all the daemons. An example of the default format is
64 2012-01-27T16:35:17Z. ovs-appctl can be used to change the default
66 - The syntax of commands and options to set log levels was simplified,
67 to make it easier to remember.
68 - New support for limiting the number of flows in an OpenFlow flow
69 table, with configurable policy for evicting flows upon
70 overflow. See the Flow_Table table in ovs-vswitch.conf.db(5)
72 - New "enable-async-messages" column in the Controller table. If set to
73 false, OpenFlow connections to the controller will initially have all
74 asynchronous messages disabled, overriding normal OpenFlow behavior.
75 - ofproto-provider interface:
76 - "struct rule" has a new member "used" that ofproto implementations
77 should maintain by updating with ofproto_rule_update_used().
79 - The new option --timestamp causes the "monitor" command to print
80 a timestamp with every update.
81 - CFM module CCM broadcasts can now be tagged with an 802.1p priority.
85 ------------------------
87 - Added support for querying, modifying, and deleting flows
88 based on flow cookie when using NXM.
89 - Added new NXM_PACKET_IN format.
90 - Added new NXAST_DEC_TTL action.
92 - Added daemonization support to the monitor and snoop commands.
94 - The "find" command supports new set relational operators
95 {=}, {!=}, {<}, {>}, {<=}, and {>=}.
96 - ovsdb-tool now uses the typical database and schema installation
97 directories as defaults.
101 ------------------------
102 - Compatible with Open vSwitch kernel module included in Linux 3.3.
103 - New "VLAN splinters" feature to work around buggy device drivers
104 in old Linux versions. (This feature is deprecated. When
105 broken device drivers are no longer in widespread use, we will
106 delete this feature.) See ovs-vswitchd.conf.db(5) for more
109 - Added ability to match on IPv6 flow label through NXM.
110 - Added ability to match on ECN bits in IPv4 and IPv6 through NXM.
111 - Added ability to match on TTL in IPv4 and IPv6 through NXM.
112 - Added ability to modify ECN bits in IPv4.
113 - Added ability to modify TTL in IPv4.
115 - Don't require the "normal" action to use mirrors. Traffic will
116 now be properly mirrored for any flows, regardless of their
118 - Track packet and byte statistics sent on mirrors.
119 - The sFlow implementation can now usually infer the correct agent
120 device instead of having to be told explicitly.
122 - New "fdb/flush" command to flush bridge's MAC learning table.
124 - A new distributed testing tool that allows one to diagnose performance
125 and connectivity issues. This tool currently is not included in RH or
127 - RHEL packaging now supports integration with Red Hat network scripts.
129 - Post 1.4.*, OVS will be changing the default bond mode from balance-slb
130 to active-backup. SLB bonds carry significant risks with them
131 (documented vswitchd/INTERNALS) which we want to prevent unsuspecting
132 users from running into. Users are advised to update any scripts or
133 configuration which may be negatively impacted by explicitly setting
134 the bond mode which they want to use.
138 ------------------------
140 - Added an OpenFlow extension which allows the "output" action to accept
142 - Added an OpenFlow extension for flexible learning.
143 - Bumped number of NXM registers from four to five.
145 - New "version" command to determine version of running daemon.
146 - If no argument is provided for "cfm/show", displays detailed
147 information about all interfaces with CFM enabled.
148 - If no argument is provided for "lacp/show", displays detailed
149 information about all ports with LACP enabled.
151 - New "set-if" command to modify a datapath port's configuration.
153 - The software switch now supports 255 OpenFlow tables, instead
154 of just one. By default, only table 0 is consulted, but the
155 new NXAST_RESUBMIT_TABLE action can look up in additional
156 tables. Tables 128 and above are reserved for use by the
157 switch itself; please use only tables 0 through 127.
158 - Add support for 802.1D spanning tree (STP).
159 - Fragment handling extensions:
160 - New OFPC_FRAG_NX_MATCH fragment handling mode, in which L4
161 fields are made available for matching in fragments with
163 - New NXM_NX_IP_FRAG match field for matching IP fragments (usable
164 via "ip_frag" in ovs-ofctl).
165 - New ovs-ofctl "get-frags" and "set-frags" commands to get and set
166 fragment handling policy.
167 - CAPWAP tunneling now supports an extension to transport a 64-bit key.
168 By default it remains compatible with the old version and other
169 standards-based implementations.
170 - Flow setups are now processed in a round-robin manner across ports
171 to prevent any single client from monopolizing the CPU and conducting
172 a denial of service attack.
173 - Added support for native VLAN tagging. A new "vlan_mode"
174 parameter can be set for "port". Possible values: "access",
175 "trunk", "native-tagged" and "native-untagged".
176 - test-openflowd has been removed. Please use ovs-vswitchd instead.
179 ------------------------
180 - New "ofproto" abstraction layer to ease porting to hardware
182 - Packaging for Red Hat Enterprise Linux 5.6 and 6.0.
183 - Datapath support for Linux kernels up to 3.0.
185 - New "bundle" and "bundle_load" action extensions.
187 - Implement table unique constraints.
188 - Support cooperative locking between callers.
190 - New "-s" option for "show" command prints packet and byte
191 counters for each port.
193 - New "--readd" option for "replace-flows".
195 - New "show" command to print an overview of configuration.
196 - New "comment" command to add remark that explains intentions.
197 - ovs-brcompatd has been rewritten to fix long-standing bugs.
198 - ovs-openflowd has been renamed test-openflowd and moved into the
199 tests directory. Its presence confused too many users. Please
200 use ovs-vswitchd instead.
201 - New ovs-benchmark utility to test flow setup performance.
202 - A new log level "off" has been added. Configuring a log facility
203 "off" prevents any messages from being logged to it. Previously,
204 "emer" was effectively "off" because no messages were ever logged at
205 level "emer". Now, errors that cause a process to exit are logged
207 - "configure" option --with-l26 has been renamed --with-linux, and
208 --with-l26-source has been renamed --with-linux-source. The old
209 names will be removed after the next release, so please update
211 - The "-2.6" suffix has been dropped from the datapath/linux-2.6 and
212 datapath/linux-2.6/compat-2.6 directories.
214 - Dropped support for "tun_id_from_cookie" OpenFlow extension.
215 Please use the extensible match extensions instead.
216 - Removed the Maintenance_Point and Monitor tables in an effort
217 to simplify 802.1ag configuration.
218 - Performance and scalability improvements
222 ------------------------
223 - Ability to define policies over IPv6
226 - Support for extensible match extensions to OpenFlow
228 - Support for HFSC qdisc.
229 - Queue used by in-band control can now be configured.
231 - Kernel<->userspace interface has been reworked and should be
232 close to a stable ABI now.
233 - "Port group" concept has been dropped.
234 - GRE over IPSEC tunnels
236 - New active backup bonding mode.
237 - New L4 hashing support when LACP is enabled.
238 - Source MAC hash now includes VLAN field also.
240 - Greatly improved handling of large flow tables
242 - "show" command now prints full vport configuration.
243 - "dump-groups" command removed since kernel support for
244 port groups was dropped.
246 - New commands for working with the new Managers table.
247 - "list" command enhanced with new formatting options and --columns
249 - "get" command now accepts new --id option.
250 - New "find" command.
252 - New "queue-stats" command for printing queue stats.
253 - New commands "replace-flows" and "diff-flows".
254 - Commands to add and remove flows can now read from files.
255 - New --flow-format option to enable or disable NXM.
256 - New --more option to increase OpenFlow message verbosity.
257 - Removed "tun-cookie" command, which is no longer useful.
258 - ovs-controller enhancements for testing various features.
259 - New ovs-vlan-test command for testing for Linux kernel driver VLAN
260 bugs. New ovs-vlan-bug-workaround command for enabling and
261 disabling a workaround for these driver bugs.
263 - "Resubmit" actions now update flow statistics.
264 - New "register" extension for use in matching and actions, via NXM.
265 - New "multipath" experimental action extension.
266 - New support for matching multicast Ethernet frames, via NXM.
267 - New extension for OpenFlow vendor error codes.
268 - New extension to set the QoS output queue without actually
269 sending to an output port.
270 - Open vSwitch now reports a single flow table, instead of
271 separate hash and wildcard tables. This better models the
272 current implementation.
273 - New experimental "note" action.
274 - New "ofproto/trace" ovs-appctl command and associated utilities
275 to ease debugging complex flow tables.
277 - Schema documentation now includes an entity-relationship diagram.
278 - The database is now garbage collected. In most tables,
279 unreferenced rows will be deleted automatically.
280 - Many tables now include statistics updated periodically by
281 ovs-vswitchd or ovsdb-server.
282 - Every table now has an "external-ids" column for use by OVS
284 - There is no default controller anymore. Each bridge must have its
285 controller individually specified.
286 - The "fail-mode" is now a property of a Bridge instead of a Controller.
287 - New versioning and checksum features.
288 - New Managers table and manager_options column in Open_vSwitch table
289 for specifying managers. The old "managers" column in the
290 Open_vSwitch table has been removed.
291 - Many "name" columns are now immutable.
293 - Dropped support for XenServer pre-5.6.100.
294 - Dropped support for Linux pre-2.6.18.
295 - Dropped controller discovery support.
296 - Dropped "ovs-ofctl status" and the OpenFlow extension that it used.
297 Statistics reporting in the database is a rough equivalent.
298 - Dropped the "corekeeper" package (now separate, at
299 http://openvswitch.org/cgi-bin/gitweb.cgi?p=corekeeper).
300 - Performance and scalability improvements
303 v1.1.0pre2 - 13 Sep 2010
304 ------------------------
307 v1.1.0pre1 - 31 Aug 2010
308 ------------------------
309 - OpenFlow 1.0 slicing (QoS) functionality
310 - Python bindings for configuration database (no write support)
311 - Performance and scalability improvements
316 - New "patch" interface type
321 - Configuration database with remote management
324 - Support for XenServer 5.5 and 5.6
325 - Performance and scalability improvements
328 v0.99.2 - 18 Feb 2010
329 ---------------------
332 v0.99.1 - 25 Jan 2010
333 ---------------------
334 - Add support for sFlow(R)
335 - Make headers compatible with C++
338 v0.99.0 - 14 Jan 2010
339 ---------------------
340 - User-space forwarding engine
343 v0.90.7 - 29 Nov 2009
344 ---------------------
345 - Add support for NetFlow active timeouts
352 v0.90.5 - 21 Sep 2009
353 ---------------------
354 - Generalize in-band control to more diverse network setups